Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,208
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0065 # 04 Y:1993 | 04 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $200 | $800 | Not Implemented |
UF0065 # 05 Y:1993 | 05 | 1993 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,871 | $5,900 | Not Implemented |
UF0065 # 06 Y:1993 | 06 | 1993 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,015 | $3,000 | Not Implemented |
KU0398 # 01 Y:1993 | 01 | 1993 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $45,950 | $48,000 | Not Implemented |
KU0398 # 02 Y:1993 | 02 | 1993 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $17,158 | $19,000 | Not Implemented |
KU0398 # 03 Y:1993 | 03 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,620 | $2,000 | Implemented |
KU0398 # 04 Y:1993 | 04 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,875 | $2,875 | Implemented |
KU0398 # 05 Y:1993 | 05 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,003 | $19,646 | Implemented |
KU0398 # 06 Y:1993 | 06 | 1993 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $1,349 | $700 | Implemented |
KU0398 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $340 | $0 | Implemented |
KU0398 # 08 Y:1993 | 08 | 1993 | USE PHOTOCELL CONTROLS | $835 | $400 | Not Implemented |
KU0398 # 09 Y:1993 | 09 | 1993 | INSTALL OCCUPANCY SENSORS | $769 | $1,260 | Not Implemented |
KU0398 # 10 Y:1993 | 10 | 1993 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $100 | $10 | Implemented |
ND0153 # 01 Y:1993 | 01 | 1993 | REPLACE ELECTRIC MOTORS WITH BACK PRESSURE STEAM TURBINES AND USE EXHAUST STEAM FOR PROCESS HEAT | $48,899 | $0 | Not Implemented |
ND0153 # 02 Y:1993 | 02 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,413 | $6,235 | Implemented |
ND0153 # 03 Y:1993 | 03 | 1993 | USE UTILITY CONTROLLED POWER MANAGEMENT | $12,899 | $0 | Implemented |
ND0153 # 04 Y:1993 | 04 | 1993 | INSTALL / REPAIR INSULATION ON STEAM LINES | $12,527 | $1,413 | Not Implemented |
ND0153 # 05 Y:1993 | 05 | 1993 | OPTIMIZE PLANT POWER FACTOR | $11,871 | $16,760 | Implemented |
ND0153 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,992 | $1,262 | Implemented |
ND0153 # 07 Y:1993 | 07 | 1993 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $225 | $218 | Implemented |
WI0179 # 01 Y:1993 | 01 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,974 | $4,960 | Not Implemented |
WI0179 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,295 | $5,659 | Not Implemented |
WI0179 # 03 Y:1993 | 03 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,270 | $0 | Implemented |
WI0179 # 04 Y:1993 | 04 | 1993 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,354 | $2,800 | Not Implemented |
WI0179 # 05 Y:1993 | 05 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $776 | $500 | Not Implemented |