Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,208
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0179 # 02 Y:1993 | 02 | 1993 | USE RADIANT HEATER FOR SPOT HEATING | $14,970 | $10,890 | Not Implemented |
AM0179 # 03 Y:1993 | 03 | 1993 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,850 | $0 | Implemented |
AM0179 # 04 Y:1993 | 04 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,280 | $500 | Implemented |
AM0179 # 05 Y:1993 | 05 | 1993 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,640 | $0 | Not Implemented |
AM0179 # 06 Y:1993 | 06 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,210 | $1,230 | Not Implemented |
AM0179 # 07 Y:1993 | 07 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $760 | $3,920 | Not Implemented |
WV0001 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $241 | $144 | Implemented |
WV0001 # 02 Y:1993 | 02 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $457 | $930 | Implemented |
WV0001 # 03 Y:1993 | 03 | 1993 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $140 | $170 | Implemented |
WV0001 # 04 Y:1993 | 04 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $120 | $60 | Implemented |
WV0001 # 05 Y:1993 | 05 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $480 | $450 | Implemented |
WV0001 # 06 Y:1993 | 06 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $36 | $30 | Implemented |
SD0054 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,157 | $3,130 | Implemented |
SD0054 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $34,190 | $440 | Implemented |
SD0054 # 03 Y:1993 | 03 | 1993 | INSULATE BARE EQUIPMENT | $4,096 | $7,642 | Not Implemented |
SD0054 # 04 Y:1993 | 04 | 1993 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $6,910 | $12,725 | Not Implemented |
SD0054 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,930 | $0 | Implemented |
SD0054 # 06 Y:1993 | 06 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $7,440 | $9,720 | Implemented |
SD0054 # 07 Y:1993 | 07 | 1993 | INSTALL SET-BACK TIMERS | $4,573 | $4,480 | Implemented |
SD0054 # 08 Y:1993 | 08 | 1993 | INSTALL SET-BACK TIMERS | $826 | $230 | Not Implemented |
SD0054 # 09 Y:1993 | 09 | 1993 | INSTALL SET-BACK TIMERS | $1,033 | $0 | Implemented |
AM0178 # 01 Y:1993 | 01 | 1993 | OPTIMIZE PLANT POWER FACTOR | $48,960 | $72,000 | Not Implemented |
AM0178 # 02 Y:1993 | 02 | 1993 | OPTIMIZE PLANT POWER FACTOR | $34,000 | $38,500 | Implemented |
AM0178 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,960 | $600 | Not Implemented |
AM0178 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,760 | $24,300 | Not Implemented |