Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,208
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0446 # 02 Y:1991 | 02 | 1991 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $439 | $140 | Implemented |
GT0446 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,377 | $0 | Implemented |
GT0446 # 04 Y:1991 | 04 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $120 | $30 | Implemented |
GT0446 # 05 Y:1991 | 05 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $18,000 | $300 | Implemented |
GT0446 # 06 Y:1991 | 06 | 1991 | INSTALL / REPAIR INSULATION ON STEAM LINES | $80 | $130 | Implemented |
GT0446 # 07 Y:1991 | 07 | 1991 | COVER OPEN TANKS | $9,880 | $7,550 | Implemented |
KU0351 # 01 Y:1991 | 01 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $5,020 | $3,380 | Implemented |
KU0351 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,664 | $744 | Implemented |
KU0351 # 03 Y:1991 | 03 | 1991 | INSTALL SET-BACK TIMERS | $693 | $400 | Implemented |
KU0351 # 04 Y:1991 | 04 | 1991 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,047 | $1,600 | Implemented |
KU0351 # 05 Y:1991 | 05 | 1991 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $662 | $0 | Implemented |
RU0120 # 01 Y:1991 | 01 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $922 | $0 | Not Implemented |
RU0120 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $560 | $136 | Not Implemented |
RU0120 # 03 Y:1991 | 03 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,940 | $0 | Not Implemented |
RU0120 # 04 Y:1991 | 04 | 1991 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $23,037 | $113,640 | Not Implemented |
RU0120 # 05 Y:1991 | 05 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $853 | $11,328 | Not Implemented |
SD0006 # 01 Y:1991 | 01 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $490 | $605 | Not Implemented |
SD0006 # 02 Y:1991 | 02 | 1991 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $424 | $700 | Not Implemented |
SD0006 # 03 Y:1991 | 03 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,921 | $3,500 | Not Implemented |
SD0006 # 04 Y:1991 | 04 | 1991 | INSTALL SET-BACK TIMERS | $2,292 | $3,750 | Not Implemented |
SD0006 # 05 Y:1991 | 05 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $5,786 | $7,500 | Not Implemented |
SD0006 # 06 Y:1991 | 06 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $405 | $1,672 | Not Implemented |
SD0006 # 07 Y:1991 | 07 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16 | $21 | Not Implemented |
SD0006 # 08 Y:1991 | 08 | 1991 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $3,470 | $600 | Not Implemented |
SD0006 # 09 Y:1991 | 09 | 1991 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $653 | $1,500 | Not Implemented |