Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,208
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0244 # 05 Y:1988 | 05 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $1,766 | $1,040 | Implemented |
OK0244 # 06 Y:1988 | 06 | 1988 | INSTALL SET-BACK TIMERS | $415 | $115 | Implemented |
OK0244 # 07 Y:1988 | 07 | 1988 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $172 | $20 | Not Implemented |
OK0244 # 08 Y:1988 | 08 | 1988 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $717 | $380 | Not Implemented |
OK0244 # 09 Y:1988 | 09 | 1988 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $332 | $275 | Implemented |
OK0247 # 01 Y:1988 | 01 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $147 | $400 | Implemented |
OK0247 # 02 Y:1988 | 02 | 1988 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,492 | $0 | Not Implemented |
OK0247 # 03 Y:1988 | 03 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $574 | $0 | Implemented |
OK0247 # 04 Y:1988 | 04 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,222 | $645 | Implemented |
OK0247 # 05 Y:1988 | 05 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $332 | $142 | Implemented |
OK0247 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $212 | $447 | Implemented |
AM0020 # 01 Y:1988 | 01 | 1988 | INSULATE BARE EQUIPMENT | $2,009 | $3,919 | Not Implemented |
AM0020 # 02 Y:1988 | 02 | 1988 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,198 | $2,000 | Implemented |
AM0020 # 03 Y:1988 | 03 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $939 | $520 | Implemented |
AM0020 # 04 Y:1988 | 04 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $360 | $0 | Implemented |
AM0020 # 05 Y:1988 | 05 | 1988 | IMPROVE LUBRICATION PRACTICES | $230 | $0 | Implemented |
UD0252 # 01 Y:1988 | 01 | 1988 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $25,000 | $0 | Implemented |
UD0252 # 02 Y:1988 | 02 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $638 | $902 | Implemented |
UD0252 # 03 Y:1988 | 03 | 1988 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $508 | $600 | Implemented |
UD0252 # 04 Y:1988 | 04 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,667 | $9,550 | Implemented |
UD0252 # 05 Y:1988 | 05 | 1988 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $665 | $728 | Not Implemented |
UD0252 # 06 Y:1988 | 06 | 1988 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,267 | $4,098 | Implemented |
UD0252 # 07 Y:1988 | 07 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $506 | $1,000 | Implemented |
WI0015 # 01 Y:1987 | 01 | 1987 | IMPROVE LUBRICATION PRACTICES | $1,228 | $0 | Implemented |
WI0015 # 02 Y:1987 | 02 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $769 | $0 | Implemented |