Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,092
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0214 # 04 Y:1987 | 04 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,800 | $1,155 | Not Implemented |
OK0214 # 05 Y:1987 | 05 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,319 | $0 | Implemented |
OK0214 # 06 Y:1987 | 06 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $870 | $230 | Not Implemented |
OK0214 # 07 Y:1987 | 07 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $1,059 | $450 | Implemented |
UD0224 # 01 Y:1987 | 01 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,584 | $0 | Not Implemented |
UD0224 # 02 Y:1987 | 02 | 1987 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,048 | $7,200 | Not Implemented |
UD0224 # 03 Y:1987 | 03 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,509 | $6,000 | Not Implemented |
UD0224 # 04 Y:1987 | 04 | 1987 | REDUCE GLAZED AREAS IN BUILDINGS | $3,429 | $5,800 | Not Implemented |
UD0224 # 05 Y:1987 | 05 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,313 | $2,500 | Implemented |
AT0063 # 01 Y:1987 | 01 | 1987 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $16,207 | $5,000 | Implemented |
AT0063 # 02 Y:1987 | 02 | 1987 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,078 | $500 | Not Implemented |
AT0063 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,247 | $3,793 | Implemented |
AT0063 # 04 Y:1987 | 04 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $716 | $300 | Implemented |
AT0063 # 05 Y:1987 | 05 | 1987 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $763 | $500 | Implemented |
AT0063 # 06 Y:1987 | 06 | 1987 | INSTALL AUTOMATIC STACK DAMPER | $346 | $800 | Not Implemented |
AT0063 # 07 Y:1987 | 07 | 1987 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $103 | $195 | Implemented |
AT0063 # 08 Y:1987 | 08 | 1987 | UPGRADE OBSOLETE EQUIPMENT | $200 | $0 | Implemented |
AT0063 # 09 Y:1987 | 09 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $117 | $0 | Not Implemented |
AT0063 # 10 Y:1987 | 10 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $117 | $200 | Implemented |
AT0063 # 11 Y:1987 | 11 | 1987 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $100 | $0 | Implemented |
UD0222 # 01 Y:1987 | 01 | 1987 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $50,976 | $0 | Implemented |
UD0222 # 02 Y:1987 | 02 | 1987 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $12,018 | $6,000 | Not Implemented |
UD0222 # 03 Y:1987 | 03 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,028 | $25,000 | Implemented |
UD0222 # 04 Y:1987 | 04 | 1987 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $26,250 | $27,000 | Implemented |
UD0222 # 05 Y:1987 | 05 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,938 | $16,000 | Implemented |