Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20,208
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0249 # 03 Y:1985 | 03 | 1985 | USE MINIMUM STEAM OPERATING PRESSURE | $1,482 | $0 | Implemented |
TN0249 # 04 Y:1985 | 04 | 1985 | INSULATE BARE EQUIPMENT | $984 | $277 | Implemented |
TN0249 # 05 Y:1985 | 05 | 1985 | COVER OPEN TANKS | $843 | $100 | Not Implemented |
TN0249 # 06 Y:1985 | 06 | 1985 | INSULATE BARE EQUIPMENT | $449 | $172 | Implemented |
TN0249 # 07 Y:1985 | 07 | 1985 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $138 | $40 | Implemented |
TN0249 # 08 Y:1985 | 08 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $393 | $1,350 | Not Implemented |
UD0158 # 01 Y:1985 | 01 | 1985 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,705 | $1,260 | Implemented |
UD0158 # 02 Y:1985 | 02 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $434 | $280 | Implemented |
UD0158 # 03 Y:1985 | 03 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,850 | $18,000 | Not Implemented |
UD0158 # 04 Y:1985 | 04 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $327 | $240 | Implemented |
OK0160 # 01 Y:1985 | 01 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $622 | $100 | Implemented |
OK0160 # 02 Y:1985 | 02 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,464 | $300 | Implemented |
OK0160 # 03 Y:1985 | 03 | 1985 | USE RADIANT HEATER FOR SPOT HEATING | $2,869 | $5,000 | Not Implemented |
OK0160 # 04 Y:1985 | 04 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $386 | $500 | Not Implemented |
OK0162 # 01 Y:1985 | 01 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $6,361 | $1,022 | Not Implemented |
OK0162 # 02 Y:1985 | 02 | 1985 | OPTIMIZE PLANT POWER FACTOR | $900 | $2,355 | Not Implemented |
OK0162 # 03 Y:1985 | 03 | 1985 | INSTALL / REPAIR INSULATION ON STEAM LINES | $799 | $400 | Not Implemented |
OK0162 # 04 Y:1985 | 04 | 1985 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $146 | $310 | Not Implemented |
OK0162 # 05 Y:1985 | 05 | 1985 | REDESIGN PROCESS | $529 | $33 | Not Implemented |
OK0162 # 06 Y:1985 | 06 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,273 | $10,000 | Not Implemented |
GT0249 # 01 Y:1985 | 01 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,317 | $500 | Implemented |
GT0249 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $940 | $277 | Implemented |
GT0249 # 03 Y:1985 | 03 | 1985 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $218 | $585 | Not Implemented |
GT0249 # 04 Y:1985 | 04 | 1985 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $277 | $150 | Implemented |
KU0155 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,743 | $948 | Implemented |