Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
487
matching recommendationsSIC | 34 | Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0438 # 02 Y:2013 | 02 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $945 | $600 | Not Implemented |
UM0438 # 01 Y:2013 | 01 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,260 | $350 | Not Implemented |
UM0438 # 04 Y:2013 | 04 | 2013 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $98,045 | $175,000 | Not Implemented |
UM0438 # 03 Y:2013 | 03 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $22,608 | $7,500 | Not Implemented |
IP0020 # 08 Y:2013 | 08 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $824 | $176 | Implemented |
IP0020 # 07 Y:2013 | 07 | 2013 | INSTALL OCCUPANCY SENSORS | $306 | $58 | Not Implemented |
IP0020 # 04 Y:2013 | 04 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,410 | $0 | Not Implemented |
IP0020 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,216 | $699 | Implemented |
IP0020 # 05 Y:2013 | 05 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,867 | $625 | Not Implemented |
IP0020 # 03 Y:2013 | 03 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,778 | $0 | Not Implemented |
IP0020 # 01 Y:2013 | 01 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,300 | $0 | Implemented |
IP0020 # 02 Y:2013 | 02 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,348 | $0 | Not Implemented |
BD0437 # 08 Y:2013 | 08 | 2013 | INSTALL TURBULATORS | $5,570 | $2,600 | Not Implemented |
BD0437 # 11 Y:2013 | 11 | 2013 | USE POWER DURING OFF-PEAK PERIODS | $268 | $60 | Not Implemented |
BD0437 # 10 Y:2013 | 10 | 2013 | INSTALL OCCUPANCY SENSORS | $510 | $1,875 | Not Implemented |
BD0437 # 09 Y:2013 | 09 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,532 | $20 | Not Implemented |
BD0437 # 07 Y:2013 | 07 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,609 | $1,000 | Not Implemented |
BD0437 # 06 Y:2013 | 06 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,643 | $10,000 | Not Implemented |
BD0437 # 05 Y:2013 | 05 | 2013 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $7,315 | $20,000 | Not Implemented |
BD0437 # 04 Y:2013 | 04 | 2013 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $19,574 | $15,000 | Not Implemented |
BD0437 # 03 Y:2013 | 03 | 2013 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $33,735 | $100,000 | Not Implemented |
BD0437 # 02 Y:2013 | 02 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $87,468 | $54,000 | Not Implemented |
BD0437 # 01 Y:2013 | 01 | 2013 | INCREASE EFFICIENCY OF TRUCKS | $168,734 | $780,000 | Not Implemented |
BD0436 # 05 Y:2013 | 05 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $238 | $20 | Not Implemented |
BD0436 # 04 Y:2013 | 04 | 2013 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $918 | $470 | Not Implemented |