Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
21
matching recommendationsSIC | 342 | Cutlery, Handtools, And Hardware |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0358 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,710 | $398 | Not Implemented |
MS0358 # 03 Y:2010 | 03 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,482 | $274,410 | Not Implemented |
MS0358 # 04 Y:2010 | 04 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,420 | $13,240 | Not Implemented |
MS0358 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,363 | $6,334 | Not Implemented |
MS0358 # 06 Y:2010 | 06 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $682 | $945 | Not Implemented |
MS0358 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $351 | $1,687 | Not Implemented |
MS0358 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,396 | $19,479 | Not Implemented |
MS0091 # 04 Y:1997 | 04 | 1997 | USE SYNTHETIC LUBRICANT | $3,735 | $275 | Implemented |
MS0091 # 07 Y:1997 | 07 | 1997 | USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES | $2,460 | $1,390 | Implemented |
MS0091 # 06 Y:1997 | 06 | 1997 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $26,640 | $13,000 | Not Implemented |
MS0091 # 05 Y:1997 | 05 | 1997 | USE EVAPORATION TO CONCENTRATE MATERIAL | $3,856 | $10,000 | Not Implemented |
MS0091 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,842 | $298 | Implemented |
MS0091 # 02 Y:1997 | 02 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,473 | $1,929 | Not Implemented |
MS0091 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,189 | $20,713 | Implemented |
MS0064 # 01 Y:1996 | 01 | 1996 | USE PHOTOCELL CONTROLS | $7,748 | $1,675 | Not Implemented |
MS0064 # 02 Y:1996 | 02 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,252 | $7,353 | Implemented |
MS0064 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,999 | $35,867 | Implemented |
MS0064 # 04 Y:1996 | 04 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $1,386 | $3,248 | Not Implemented |
MS0064 # 05 Y:1996 | 05 | 1996 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,928 | $320 | Not Implemented |
MS0064 # 06 Y:1996 | 06 | 1996 | RECOVER AND REUSE WASTE MATERIAL | $800 | $1,000 | Not Implemented |
MS0064 # 07 Y:1996 | 07 | 1996 | USE RE-USABLE FILTERS | $1,373 | $1,440 | Not Implemented |