IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

78

matching recommendations
Reset
SIC 342 Cutlery, Handtools, And Hardware
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0095 # 02 Y:1990 02 1990 INSULATE BARE EQUIPMENT $2,105 $2,035 Implemented
OR0095 # 01 Y:1990 01 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $658 $465 Implemented
OR0095 # 03 Y:1990 03 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $336 $345 Implemented
RU0104 # 05 Y:1990 05 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,477 $0 Implemented
RU0104 # 01 Y:1990 01 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $592 $0 Implemented
RU0104 # 03 Y:1990 03 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,006 $630 Implemented
RU0104 # 04 Y:1990 04 1990 COVER OPEN TANKS $433 $500 Implemented
RU0104 # 02 Y:1990 02 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $513 $419 Implemented
RU0104 # 06 Y:1990 06 1990 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $996 $1,250 Not Implemented
RU0104 # 07 Y:1990 07 1990 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $20,685 $63,000 Implemented
OR0095 # 05 Y:1990 05 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $296 $1,325 Not Implemented
OR0095 # 04 Y:1990 04 1990 OPTIMIZE PLANT POWER FACTOR $390 $1,050 Not Implemented
TN0409 # 01 Y:1990 01 1990 KEEP LAMPS AND REFLECTORS CLEAN $31,973 $43,388 Implemented
TN0409 # 02 Y:1990 02 1990 INSTALL TIMERS AND/OR THERMOSTATS $14,470 $1,335 Implemented
TN0409 # 08 Y:1990 08 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,788 $2,100 Implemented
TN0409 # 09 Y:1990 09 1990 INSTALL / REPAIR INSULATION ON STEAM LINES $498 $138 Implemented
TN0409 # 03 Y:1990 03 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $17,393 $1,230 Implemented
TN0409 # 07 Y:1990 07 1990 INSULATE BARE EQUIPMENT $1,728 $985 Not Implemented
TN0409 # 04 Y:1990 04 1990 CLOSE OFF UNNEEDED STEAM LINES $4,993 $0 Implemented
TN0409 # 05 Y:1990 05 1990 REPAIR AND ELIMINATE STEAM LEAKS $2,480 $1,050 Implemented
TN0409 # 06 Y:1990 06 1990 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,998 $1,000 Implemented
GT0407 # 03 Y:1990 03 1990 BURN A LESS EXPENSIVE GRADE OF FUEL $6,760 $0 Implemented
RU0090 # 06 Y:1990 06 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $176 $186 Not Implemented
GT0407 # 02 Y:1990 02 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $198 $422 Not Implemented
RU0090 # 05 Y:1990 05 1990 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $433 $0 Not Implemented