Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
29
matching recommendationsSIC | 342 | Cutlery, Handtools, And Hardware |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0070 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,339 | $8,744 | Implemented |
SD0070 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,419 | $200 | Implemented |
SD0070 # 04 Y:1993 | 04 | 1993 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $6,505 | $15,000 | Implemented |
SD0070 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $680 | $1,041 | Implemented |
SD0070 # 06 Y:1993 | 06 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $7,258 | $7,590 | Implemented |
SD0070 # 07 Y:1993 | 07 | 1993 | INSTALL SET-BACK TIMERS | $1,719 | $3,360 | Implemented |
SD0070 # 08 Y:1993 | 08 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,052 | $735 | Implemented |
SD0070 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,910 | $3,450 | Implemented |
GT0514 # 06 Y:1993 | 06 | 1993 | USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING | $13,150 | $40,000 | Not Implemented |
GT0514 # 07 Y:1993 | 07 | 1993 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $8,860 | $17,100 | Not Implemented |
GT0514 # 05 Y:1993 | 05 | 1993 | OPTIMIZE PLANT POWER FACTOR | $16,240 | $25,000 | Implemented |
GT0514 # 04 Y:1993 | 04 | 1993 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,600 | $10,000 | Not Implemented |
GT0514 # 03 Y:1993 | 03 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,450 | $900 | Implemented |
GT0514 # 02 Y:1993 | 02 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,010 | $7,520 | Implemented |
GT0514 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,380 | $14,150 | Implemented |
UD0398 # 01 Y:1993 | 01 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $16,277 | $0 | Not Implemented |
UD0398 # 02 Y:1993 | 02 | 1993 | REDUCE FLUID FLOW RATES | $7,396 | $5,000 | Implemented |
UD0398 # 03 Y:1993 | 03 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,240 | $40,000 | Not Implemented |
UD0398 # 04 Y:1993 | 04 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $156 | $200 | Implemented |
UD0398 # 05 Y:1993 | 05 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,539 | $0 | Not Implemented |
UD0398 # 06 Y:1993 | 06 | 1993 | UPGRADE CONTROLS ON COMPRESSORS | $5,166 | $800 | Implemented |
UF0060 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,244 | $46,210 | Not Implemented |
UF0060 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $719 | $2,833 | Not Implemented |
UF0060 # 03 Y:1993 | 03 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $11,130 | $11,140 | Not Implemented |
UF0060 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $281 | $238 | Not Implemented |