Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsSIC | 3423 | Hand And Edge Tools, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0103 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $35,332 | $1,960 | Not Implemented |
TT0103 # 04 Y:2012 | 04 | 2012 | STANDARDIZE MOTOR INVENTORY | $0 | $0 | Not Implemented |
TT0103 # 03 Y:2012 | 03 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $12,318 | $5,300 | Implemented |
TT0103 # 02 Y:2012 | 02 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $9,152 | $35,480 | Not Implemented |
TT0103 # 01 Y:2012 | 01 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $19,502 | $0 | Implemented |
TN0601 # 07 Y:1997 | 07 | 1997 | INSULATE BARE EQUIPMENT | $170 | $180 | Not Implemented |
TN0601 # 06 Y:1997 | 06 | 1997 | DISCONNECT BALLASTS | $1,190 | $180 | Not Implemented |
TN0601 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,045 | $0 | Implemented |
TN0601 # 04 Y:1997 | 04 | 1997 | INSULATE BARE EQUIPMENT | $2,960 | $295 | Implemented |
TN0601 # 03 Y:1997 | 03 | 1997 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $3,270 | $0 | Not Implemented |
TN0601 # 02 Y:1997 | 02 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $4,865 | $8,000 | Not Implemented |
TN0601 # 01 Y:1997 | 01 | 1997 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $13,200 | $0 | Not Implemented |
TN0361 # 11 Y:1989 | 11 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $82 | $50 | Implemented |
TN0361 # 13 Y:1989 | 13 | 1989 | OPTIMIZE PLANT POWER FACTOR | $37,840 | $35,000 | Implemented |
TN0361 # 12 Y:1989 | 12 | 1989 | INSULATE BARE EQUIPMENT | $334 | $247 | Not Implemented |
TN0361 # 10 Y:1989 | 10 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,587 | $780 | Implemented |
TN0361 # 09 Y:1989 | 09 | 1989 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $188 | $1,750 | Not Implemented |
TN0361 # 08 Y:1989 | 08 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,021 | $0 | Implemented |
TN0361 # 07 Y:1989 | 07 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $2,339 | $680 | Implemented |
TN0361 # 06 Y:1989 | 06 | 1989 | INSULATE BARE EQUIPMENT | $2,222 | $548 | Not Implemented |
TN0361 # 05 Y:1989 | 05 | 1989 | INSTALL SET-BACK TIMERS | $7,384 | $0 | Not Implemented |
TN0361 # 04 Y:1989 | 04 | 1989 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $1,833 | $3,650 | Not Implemented |
TN0361 # 03 Y:1989 | 03 | 1989 | USE RADIANT HEATER FOR SPOT HEATING | $2,488 | $5,550 | Implemented |
TN0361 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,381 | $1,110 | Implemented |
TN0361 # 01 Y:1989 | 01 | 1989 | ADJUST VENTS TO MINIMIZE ENERGY USE | $30,604 | $6,500 | Not Implemented |