Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsSIC | 3423 | Hand And Edge Tools, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0013 # 06 Y:2012 | 06 | 2012 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $28,404 | $14,713 | Not Implemented |
WM0013 # 05 Y:2012 | 05 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,980 | $1,125 | Implemented |
WM0013 # 04 Y:2012 | 04 | 2012 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $294 | $368 | Not Implemented |
WM0013 # 03 Y:2012 | 03 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $327 | $1,480 | Not Implemented |
WM0013 # 02 Y:2012 | 02 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $8,084 | $360 | Not Implemented |
WM0013 # 01 Y:2012 | 01 | 2012 | USE SYNTHETIC LUBRICANT | $31,970 | $25,000 | Implemented |
WI0439 # 06 Y:2003 | 06 | 2003 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,084 | $1,200 | Not Implemented |
WI0439 # 05 Y:2003 | 05 | 2003 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $1,726 | $0 | Not Implemented |
WI0439 # 04 Y:2003 | 04 | 2003 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,921 | $608 | Not Implemented |
WI0439 # 03 Y:2003 | 03 | 2003 | INSTALL OCCUPANCY SENSORS | $2,560 | $9,600 | Not Implemented |
WI0439 # 02 Y:2003 | 02 | 2003 | INSTALL OCCUPANCY SENSORS | $537 | $75 | Not Implemented |
WI0439 # 01 Y:2003 | 01 | 2003 | INSTALL OCCUPANCY SENSORS | $2,581 | $5,500 | Implemented |
WI0155 # 08 Y:1992 | 08 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $349 | $0 | Not Implemented |
WI0155 # 09 Y:1992 | 09 | 1992 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,301 | $0 | Not Implemented |
WI0155 # 07 Y:1992 | 07 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $381 | $1,280 | Not Implemented |
WI0155 # 06 Y:1992 | 06 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $844 | $2,000 | Not Implemented |
WI0155 # 05 Y:1992 | 05 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,483 | $0 | Not Implemented |
WI0155 # 04 Y:1992 | 04 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,583 | $2,800 | Not Implemented |
WI0155 # 03 Y:1992 | 03 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,747 | $500 | Implemented |
WI0155 # 02 Y:1992 | 02 | 1992 | INSTALL SET-BACK TIMERS | $370 | $400 | Not Implemented |
WI0155 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $395 | $5 | Not Implemented |
WI0005 # 01 Y:1987 | 01 | 1987 | IMPROVE LUBRICATION PRACTICES | $5,838 | $0 | Implemented |
WI0005 # 06 Y:1987 | 06 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $44 | $0 | Implemented |
WI0005 # 05 Y:1987 | 05 | 1987 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,319 | $2,700 | Not Implemented |
WI0005 # 04 Y:1987 | 04 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $466 | $620 | Implemented |