Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsSIC | 3429 | Hardware, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0275 # 04 Y:1997 | 04 | 1997 | OPTIMIZE PLANT POWER FACTOR | $7,023 | $15,339 | Not Implemented |
ND0275 # 17 Y:1997 | 17 | 1997 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $91 | $50 | Not Implemented |
ND0275 # 16 Y:1997 | 16 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $360 | $0 | Not Implemented |
ND0275 # 15 Y:1997 | 15 | 1997 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $528 | $450 | Not Implemented |
ND0275 # 14 Y:1997 | 14 | 1997 | PAY BILLS ON TIME TO AVOID LATE FEES | $3 | $0 | Not Implemented |
ND0275 # 13 Y:1997 | 13 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $55 | $0 | Not Implemented |
ND0275 # 12 Y:1997 | 12 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $149 | $60 | Not Implemented |
ND0275 # 11 Y:1997 | 11 | 1997 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $276 | $0 | Not Implemented |
ND0275 # 10 Y:1997 | 10 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $324 | $363 | Not Implemented |
ND0275 # 09 Y:1997 | 09 | 1997 | INSTALL OCCUPANCY SENSORS | $652 | $600 | Not Implemented |
ND0275 # 08 Y:1997 | 08 | 1997 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $1,310 | $330 | Not Implemented |
ND0275 # 07 Y:1997 | 07 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,266 | $400 | Not Implemented |
ND0275 # 06 Y:1997 | 06 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,175 | $993 | Implemented |
ND0275 # 05 Y:1997 | 05 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,117 | $4,500 | Implemented |
ND0275 # 03 Y:1997 | 03 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,561 | $1,435 | Implemented |
ND0275 # 02 Y:1997 | 02 | 1997 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $217,807 | $100,000 | Implemented |
ND0275 # 01 Y:1997 | 01 | 1997 | ADOPT IN-HOUSE MATERIAL GENERATION | $1,307,600 | $1,300,000 | Not Implemented |
NC0114 # 01 Y:1997 | 01 | 1997 | COVER OPEN TANKS | $359 | $195 | Not Implemented |
NC0114 # 11 Y:1997 | 11 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $93,603 | $14,305 | Not Implemented |
NC0114 # 10 Y:1997 | 10 | 1997 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $4,888 | $10,500 | Implemented |
NC0114 # 09 Y:1997 | 09 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $3,150 | $1,096 | Implemented |
NC0114 # 08 Y:1997 | 08 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,459 | $5,200 | Implemented |
NC0114 # 07 Y:1997 | 07 | 1997 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $605 | $250 | Implemented |
NC0114 # 06 Y:1997 | 06 | 1997 | USE EVAPORATION TO CONCENTRATE MATERIAL | $9,198 | $12,000 | Not Implemented |
NC0114 # 05 Y:1997 | 05 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $110 | $56 | Not Implemented |