Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

271

matching recommendations
Reset
SIC 3432 Plumbing Fixture Fittings And Trim
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
RU0039 # 05 Y:1988 05 1988 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,235 $1,040 Not Implemented
RU0039 # 06 Y:1988 06 1988 INSULATE BARE EQUIPMENT $248 $501 Not Implemented
RU0039 # 07 Y:1988 07 1988 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $3,785 $1,260 Implemented
RU0039 # 08 Y:1988 08 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $116 $0 Implemented
RU0039 # 09 Y:1988 09 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $765 $0 Implemented
WI0008 # 01 Y:1987 01 1987 IMPROVE LUBRICATION PRACTICES $562 $0 Not Implemented
WI0008 # 02 Y:1987 02 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $269 $0 Implemented
WI0008 # 03 Y:1987 03 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $644 $701 Implemented
WI0008 # 04 Y:1987 04 1987 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $122 $0 Implemented
WI0008 # 05 Y:1987 05 1987 USE DEMAND CONTROLLER OR LOAD SHEDDER $2,563 $5,000 Not Implemented
WI0008 # 07 Y:1987 07 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $695 $500 Implemented
MA0067 # 01 Y:1986 01 1986 AIR CONDITION ONLY SPACE NECESSARY $262 $0 Implemented
MA0067 # 02 Y:1986 02 1986 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $125 $150 Not Implemented
MA0067 # 03 Y:1986 03 1986 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $484 $900 Implemented
MA0067 # 04 Y:1986 04 1986 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,076 $7,000 Not Implemented
MA0067 # 05 Y:1986 05 1986 RECOVER WASTE HEAT FROM EQUIPMENT $1,611 $4,710 Not Implemented
TS0031 # 01 Y:1985 01 1985 OPTIMIZE PLANT POWER FACTOR $18,150 $13,550 Not Implemented
TS0031 # 02 Y:1985 02 1985 RECOVER WASTE HEAT FROM EQUIPMENT $2,504 $3,500 Not Implemented
TS0031 # 03 Y:1985 03 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,147 $50 Not Implemented
TS0031 # 04 Y:1985 04 1985 REDUCE GLAZED AREAS IN BUILDINGS $1,681 $1,360 Not Implemented
TS0031 # 05 Y:1985 05 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,076 $280 Not Implemented
TS0031 # 06 Y:1985 06 1985 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $3,081 $500 Not Implemented
UD0178 # 01 Y:1985 01 1985 COVER OPEN TANKS $2,265 $740 Not Implemented
UD0178 # 02 Y:1985 02 1985 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $3,261 $3,000 Not Implemented
UD0178 # 03 Y:1985 03 1985 LOWER CEILING TO REDUCE CONDITIONED SPACE $414 $1,250 Not Implemented