Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

175

matching recommendations
Reset
SIC 3433 Heating Equipment, Except Electric
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0079 # 08 Y:1990 08 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $46 $17 Implemented
GT0329 # 07 Y:1987 07 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $357 $1,282 Implemented
MA0087 # 09 Y:1987 09 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,536 $1,350 Implemented
OK0216 # 02 Y:1987 02 1987 INSTALL TIMERS AND/OR THERMOSTATS $4,180 $2,250 Implemented
OK0216 # 03 Y:1987 03 1987 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $753 $0 Implemented
OK0216 # 04 Y:1987 04 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $97 $60 Implemented
OK0216 # 05 Y:1987 05 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,363 $5,742 Implemented
OK0216 # 06 Y:1987 06 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,905 $0 Implemented
TN0295 # 02 Y:1986 02 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,368 $750 Implemented
TN0295 # 03 Y:1986 03 1986 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $12,728 $2,700 Implemented
TN0295 # 04 Y:1986 04 1986 INSTALL SET-BACK TIMERS $3,137 $0 Implemented
TN0288 # 03 Y:1986 03 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $881 $120 Implemented
TN0288 # 04 Y:1986 04 1986 INSTALL SET-BACK TIMERS $534 $0 Implemented
TN0288 # 05 Y:1986 05 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $537 $236 Implemented
TN0288 # 06 Y:1986 06 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $223 $600 Implemented
OK0204 # 01 Y:1986 01 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $178 $144 Implemented
OK0204 # 02 Y:1986 02 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $372 $0 Implemented
OK0204 # 03 Y:1986 03 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,377 $545 Implemented
OK0204 # 04 Y:1986 04 1986 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $635 $100 Implemented
OK0204 # 05 Y:1986 05 1986 INSTALL TIMERS AND/OR THERMOSTATS $690 $0 Implemented
OK0204 # 06 Y:1986 06 1986 INSTALL TIMERS AND/OR THERMOSTATS $7,184 $4,000 Implemented
ST0062 # 01 Y:1986 01 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,343 $537 Implemented
ST0062 # 02 Y:1986 02 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,642 $0 Implemented
ST0062 # 06 Y:1986 06 1986 INSTALL TIMERS AND/OR THERMOSTATS $2,605 $1,500 Implemented
ST0062 # 07 Y:1986 07 1986 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,765 $651 Implemented