Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
46
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0042 # 08 Y:1988 | 08 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $76 | $220 | Implemented |
AM0042 # 05 Y:1988 | 05 | 1988 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $520 | $520 | Implemented |
AM0042 # 01 Y:1988 | 01 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,470 | $150 | Implemented |
AM0042 # 02 Y:1988 | 02 | 1988 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $1,935 | $10,000 | Implemented |
LT0126 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $68 | $53 | Implemented |
CO0129 # 01 Y:1988 | 01 | 1988 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,473 | $77 | Implemented |
CO0129 # 05 Y:1988 | 05 | 1988 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $307 | $500 | Implemented |
CO0129 # 07 Y:1988 | 07 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $191 | $150 | Implemented |
CO0129 # 08 Y:1988 | 08 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $401 | $393 | Implemented |
CO0129 # 06 Y:1988 | 06 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $260 | $750 | Implemented |
CO0129 # 02 Y:1988 | 02 | 1988 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $620 | $177 | Implemented |
CO0129 # 04 Y:1988 | 04 | 1988 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $600 | $800 | Implemented |
LT0126 # 06 Y:1988 | 06 | 1988 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $324 | $100 | Implemented |
LT0126 # 05 Y:1988 | 05 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $1,541 | $600 | Implemented |
LT0126 # 01 Y:1988 | 01 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $88 | $135 | Implemented |
WI0032 # 04 Y:1988 | 04 | 1988 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,240 | $0 | Implemented |
WI0032 # 03 Y:1988 | 03 | 1988 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $912 | $0 | Implemented |
UD0264 # 01 Y:1988 | 01 | 1988 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $677 | $0 | Implemented |
UD0264 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,732 | $3,790 | Implemented |
UD0264 # 04 Y:1988 | 04 | 1988 | INSTALL STORM WINDOWS AND DOORS | $984 | $929 | Implemented |
WI0032 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,304 | $0 | Implemented |
OK0253 # 01 Y:1988 | 01 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $5,363 | $1,200 | Implemented |
AT0104 # 08 Y:1988 | 08 | 1988 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $187 | $0 | Implemented |
OK0253 # 05 Y:1988 | 05 | 1988 | USE RADIANT HEATER FOR SPOT HEATING | $4,721 | $13,000 | Implemented |
OK0253 # 06 Y:1988 | 06 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,613 | $0 | Implemented |