Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,509
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0193 # 04 Y:2000 | 04 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,402 | $5,673 | Not Implemented |
SF0193 # 05 Y:2000 | 05 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,316 | $6,961 | Not Implemented |
SF0193 # 06 Y:2000 | 06 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,201 | $9,000 | Implemented |
SF0193 # 07 Y:2000 | 07 | 2000 | USE ALTERNATIVE FLOCCULENT TO MINIMIZE SLUDGE VOLUME | $8,950 | $16,000 | Not Implemented |
SD0249 # 01 Y:2000 | 01 | 2000 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $12,372 | $25 | Implemented |
SD0249 # 02 Y:2000 | 02 | 2000 | UPGRADE CONTROLS ON COMPRESSORS | $898 | $600 | Implemented |
SD0249 # 03 Y:2000 | 03 | 2000 | AUTOMATE FINISHING PROCESS | $62,250 | $100,000 | Not Implemented |
SD0249 # 04 Y:2000 | 04 | 2000 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $25,500 | $23,000 | Not Implemented |
ND0349 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,863 | $9,787 | Implemented |
ND0349 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $681 | $1,600 | Implemented |
ND0349 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $394 | $420 | Not Implemented |
ND0349 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $917 | $50 | Implemented |
ND0349 # 05 Y:2000 | 05 | 2000 | USE PHOTOCELL CONTROLS | $92 | $300 | Implemented |
ND0349 # 06 Y:2000 | 06 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $302 | $90 | Implemented |
ND0349 # 07 Y:2000 | 07 | 2000 | USE EVAPORATION TO CONCENTRATE MATERIAL | $746 | $250 | Not Implemented |
ND0349 # 08 Y:2000 | 08 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $210 | $200 | Not Implemented |
ND0349 # 09 Y:2000 | 09 | 2000 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $967 | $0 | Not Implemented |
AM0374 # 01 Y:2000 | 01 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,510 | $350 | Not Implemented |
AM0374 # 02 Y:2000 | 02 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,670 | $910 | Not Implemented |
AM0374 # 03 Y:2000 | 03 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,080 | $0 | Not Implemented |
AM0374 # 04 Y:2000 | 04 | 2000 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $1,010 | $610 | Implemented |
AM0374 # 05 Y:2000 | 05 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $930 | $78 | Implemented |
AM0374 # 06 Y:2000 | 06 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $470 | $155 | Implemented |
SD0247 # 01 Y:2000 | 01 | 2000 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $11,396 | $8,250 | Not Implemented |
SD0247 # 02 Y:2000 | 02 | 2000 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,905 | $3,000 | Not Implemented |