IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,509

matching recommendations
Reset
SIC 344 Fabricated Structural Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0247 # 03 Y:2000 03 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,007 $0 Not Implemented
SD0247 # 04 Y:2000 04 2000 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $5,628 $3,000 Not Implemented
SD0247 # 05 Y:2000 05 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,279 $1,800 Not Implemented
SD0247 # 06 Y:2000 06 2000 INSULATE BARE EQUIPMENT $570 $1,030 Not Implemented
SD0247 # 07 Y:2000 07 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $3,440 $12,500 Not Implemented
SD0247 # 08 Y:2000 08 2000 CONTRACT A WOOD PALLET RECYCLING COMPANY $6,916 $0 Not Implemented
SD0247 # 09 Y:2000 09 2000 IMPROVE SPACE COMFORT CONDITIONING $32,000 $10,380 Not Implemented
SD0242 # 01 Y:2000 01 2000 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $14,399 $1,960 Implemented
SD0242 # 02 Y:2000 02 2000 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $14,283 $3,000 Not Implemented
SD0242 # 03 Y:2000 03 2000 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,568 $0 Not Implemented
SD0242 # 04 Y:2000 04 2000 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,903 $0 Implemented
SD0242 # 05 Y:2000 05 2000 CONVERT TO ELECTROSTATIC POWDER COATING $42,700 $58,000 Not Implemented
SD0242 # 06 Y:2000 06 2000 CONVERT TO AQUEOUS CLEANING SYSTEM $8,347 $0 Not Implemented
SD0242 # 07 Y:2000 07 2000 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $2,533 $8,500 Implemented
SD0242 # 08 Y:2000 08 2000 RECYCLE WHITE WATER $313 $400 Not Implemented
SD0242 # 09 Y:2000 09 2000 USE ONLY AMOUNT OF PACKAGING MATERIAL NECESSARY $2,431 $3,294 Not Implemented
NV0148 # 01 Y:2000 01 2000 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $768 $1,500 Implemented
NV0148 # 02 Y:2000 02 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,562 $22,374 Implemented
NV0148 # 03 Y:2000 03 2000 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,341 $1,391 Not Implemented
NV0148 # 04 Y:2000 04 2000 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $704 $0 Implemented
TP0012 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,884 $0 n/a
TP0012 # 02 Y:2000 02 2000 OPTIMIZE PLANT POWER FACTOR $992 $1,750 n/a
TP0012 # 03 Y:2000 03 2000 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $4,665 $9,759 n/a
TP0012 # 04 Y:2000 04 2000 INSTALL OCCUPANCY SENSORS $3,468 $1,720 n/a
TP0012 # 05 Y:2000 05 2000 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,241 $0 n/a