Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,509
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0125 # 05 Y:1995 | 05 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $307 | $966 | Implemented |
UF0125 # 06 Y:1995 | 06 | 1995 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $114 | $250 | Implemented |
OR0247 # 01 Y:1995 | 01 | 1995 | UPGRADE CONTROLS ON COMPRESSORS | $10,230 | $5,900 | Implemented |
OR0247 # 02 Y:1995 | 02 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,211 | $3,000 | Implemented |
OR0247 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $374 | $521 | Implemented |
OR0247 # 04 Y:1995 | 04 | 1995 | OPTIMIZE PLANT POWER FACTOR | $2,538 | $7,200 | Not Implemented |
OR0247 # 05 Y:1995 | 05 | 1995 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $23,384 | $10,772 | Implemented |
OR0247 # 06 Y:1995 | 06 | 1995 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $6,900 | $0 | Implemented |
UF0123 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,722 | $9,249 | Not Implemented |
UF0123 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,429 | $23,286 | Implemented |
UF0123 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $167 | $280 | Implemented |
UF0123 # 04 Y:1995 | 04 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,838 | $15,023 | Implemented |
UF0123 # 05 Y:1995 | 05 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,737 | $850 | Implemented |
UF0123 # 06 Y:1995 | 06 | 1995 | CONVERT LIQUID HEATERS FROM UNDERFIRING TO IMMERSION OR SUBMERSION HEATING | $12,460 | $11,600 | Not Implemented |
UF0123 # 07 Y:1995 | 07 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $17,287 | $35,300 | Not Implemented |
UF0123 # 08 Y:1995 | 08 | 1995 | USE PHOTOCELL CONTROLS | $2,518 | $400 | Implemented |
UF0123 # 09 Y:1995 | 09 | 1995 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $36,323 | $8,765 | Implemented |
UF0123 # 10 Y:1995 | 10 | 1995 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $5,121 | $8,000 | Not Implemented |
UF0123 # 11 Y:1995 | 11 | 1995 | PAY BILLS ON TIME TO AVOID LATE FEES | $3,769 | $0 | Implemented |
UF0123 # 12 Y:1995 | 12 | 1995 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $140,752 | $0 | Not Implemented |
NV0040 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,149 | $709 | Implemented |
NV0040 # 02 Y:1995 | 02 | 1995 | INSTALL SKYLIGHTS | $6,192 | $20,963 | Not Implemented |
NV0040 # 03 Y:1995 | 03 | 1995 | INSTALL OCCUPANCY SENSORS | $295 | $164 | Not Implemented |
NV0040 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $417 | $100 | Implemented |
AR0066 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,497 | $489 | Implemented |