Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,509
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0475 # 01 Y:1995 | 01 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $10,960 | $1,800 | Not Implemented |
OK0475 # 02 Y:1995 | 02 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $600 | $3,553 | Implemented |
OK0475 # 03 Y:1995 | 03 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $513 | $50 | Implemented |
OK0475 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,280 | $1,819 | Implemented |
OK0475 # 05 Y:1995 | 05 | 1995 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $14,929 | $30,000 | Not Implemented |
OK0476 # 01 Y:1995 | 01 | 1995 | USE POWER DURING OFF-PEAK PERIODS | $3,319 | $0 | Not Implemented |
OK0476 # 02 Y:1995 | 02 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,650 | $90 | Implemented |
OK0476 # 03 Y:1995 | 03 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $900 | $655 | Implemented |
OK0476 # 04 Y:1995 | 04 | 1995 | INSTALL SET-BACK TIMERS | $553 | $200 | Implemented |
OK0476 # 05 Y:1995 | 05 | 1995 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $10,856 | $36,000 | Not Implemented |
UF0127 # 01 Y:1995 | 01 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,065 | $0 | Implemented |
UF0127 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $457 | $935 | Implemented |
UF0127 # 03 Y:1995 | 03 | 1995 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $411 | $500 | Implemented |
UF0127 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $784 | $200 | Implemented |
UF0127 # 05 Y:1995 | 05 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $858 | $2,485 | Not Implemented |
UF0127 # 06 Y:1995 | 06 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $78 | $300 | Not Implemented |
UF0127 # 07 Y:1995 | 07 | 1995 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $455 | $1,450 | Not Implemented |
UD0466 # 01 Y:1995 | 01 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $627 | $1,000 | Not Implemented |
UD0466 # 02 Y:1995 | 02 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,867 | $3,000 | Not Implemented |
UD0466 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,108 | $1,530 | Not Implemented |
UD0466 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $816 | $960 | Not Implemented |
UD0466 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,117 | $640 | Not Implemented |
KG0036 # 01 Y:1995 | 01 | 1995 | USE POWER DURING OFF-PEAK PERIODS | $12,130 | $0 | Implemented |
KG0036 # 02 Y:1995 | 02 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,127 | $500 | Implemented |
KG0036 # 03 Y:1995 | 03 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $3,896 | $1,800 | Not Implemented |