Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,509
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0243 # 04 Y:1992 | 04 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $280 | $220 | Implemented |
CO0243 # 05 Y:1992 | 05 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $230 | $590 | Implemented |
CO0243 # 06 Y:1992 | 06 | 1992 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,380 | $5,600 | Implemented |
CO0243 # 07 Y:1992 | 07 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,540 | $16,210 | Implemented |
CO0243 # 08 Y:1992 | 08 | 1992 | USE MINIMUM SAFE OVEN VENTILATION | $260 | $680 | Implemented |
CO0243 # 09 Y:1992 | 09 | 1992 | INSULATE BARE EQUIPMENT | $610 | $3,410 | Implemented |
AM0151 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,535 | $6,730 | Not Implemented |
AM0151 # 02 Y:1992 | 02 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,460 | $530 | Implemented |
AM0151 # 03 Y:1992 | 03 | 1992 | PAY UTILITY BILLS ON TIME | $920 | $0 | Implemented |
AM0151 # 04 Y:1992 | 04 | 1992 | INSTALL SET-BACK TIMERS | $730 | $300 | Implemented |
AM0151 # 05 Y:1992 | 05 | 1992 | INSTALL SET-BACK TIMERS | $460 | $0 | Implemented |
AM0151 # 06 Y:1992 | 06 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $460 | $0 | Implemented |
AM0151 # 07 Y:1992 | 07 | 1992 | INSTALL SET-BACK TIMERS | $167 | $0 | Not Implemented |
KU0370 # 01 Y:1992 | 01 | 1992 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $2,059 | $2,670 | Not Implemented |
KU0370 # 02 Y:1992 | 02 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,376 | $1,450 | Implemented |
KU0370 # 03 Y:1992 | 03 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $527 | $0 | Implemented |
KU0370 # 04 Y:1992 | 04 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $313 | $1,000 | Implemented |
KU0370 # 05 Y:1992 | 05 | 1992 | REDUCE OR ELIMINATE WASTE | $999 | $0 | Not Implemented |
KU0370 # 06 Y:1992 | 06 | 1992 | REDUCE VENTILATION AIR | $243 | $650 | Not Implemented |
KU0371 # 01 Y:1992 | 01 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,723 | $850 | Implemented |
KU0371 # 02 Y:1992 | 02 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,986 | $300 | Not Implemented |
KU0371 # 03 Y:1992 | 03 | 1992 | INSULATE BARE EQUIPMENT | $1,732 | $4,032 | Not Implemented |
KU0371 # 04 Y:1992 | 04 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,300 | $949 | Not Implemented |
KU0371 # 05 Y:1992 | 05 | 1992 | INSTALL SET-BACK TIMERS | $365 | $760 | Not Implemented |
KU0371 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $57 | $0 | Implemented |