Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,504
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TS0002 # 04 Y:1984 | 04 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $4,170 | $21,500 | Not Implemented |
OK0124 # 01 Y:1984 | 01 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $5,465 | $650 | Implemented |
OK0124 # 02 Y:1984 | 02 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $130 | $30 | Implemented |
OK0124 # 03 Y:1984 | 03 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,730 | $256 | Implemented |
OK0124 # 04 Y:1984 | 04 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $56 | $0 | Implemented |
OK0124 # 05 Y:1984 | 05 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $218 | $516 | Implemented |
OK0124 # 06 Y:1984 | 06 | 1984 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $64 | $485 | Implemented |
OK0127 # 01 Y:1984 | 01 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $344 | $434 | Implemented |
OK0127 # 02 Y:1984 | 02 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $744 | $0 | Implemented |
OK0127 # 03 Y:1984 | 03 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $658 | $0 | Not Implemented |
OK0127 # 04 Y:1984 | 04 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $367 | $0 | Implemented |
UD0117 # 01 Y:1984 | 01 | 1984 | REDESIGN PROCESS | $9,920 | $18,000 | Not Implemented |
UD0117 # 02 Y:1984 | 02 | 1984 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,837 | $2,000 | Not Implemented |
UD0117 # 03 Y:1984 | 03 | 1984 | INSTALL STORM WINDOWS AND DOORS | $18,493 | $22,385 | Implemented |
UD0117 # 04 Y:1984 | 04 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,694 | $0 | Implemented |
UD0117 # 05 Y:1984 | 05 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $548 | $182 | Implemented |
KU0118 # 01 Y:1984 | 01 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,757 | $500 | Implemented |
KU0118 # 02 Y:1984 | 02 | 1984 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $4,332 | $800 | Not Implemented |
KU0118 # 03 Y:1984 | 03 | 1984 | AIR CONDITION ONLY SPACE NECESSARY | $3,948 | $700 | Not Implemented |
KU0118 # 04 Y:1984 | 04 | 1984 | INSTALL AUTOMATIC STACK DAMPER | $1,032 | $1,400 | Not Implemented |
KU0118 # 05 Y:1984 | 05 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $883 | $0 | Implemented |
KU0118 # 06 Y:1984 | 06 | 1984 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $866 | $0 | Implemented |
KU0118 # 07 Y:1984 | 07 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $463 | $0 | Implemented |
KU0118 # 08 Y:1984 | 08 | 1984 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $386 | $400 | Not Implemented |
KU0118 # 09 Y:1984 | 09 | 1984 | IMPROVE LUBRICATION PRACTICES | $386 | $500 | Not Implemented |