Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
105
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0268 # 03 Y:2003 | 03 | 2003 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $10,491 | $2,000 | Not Implemented |
NC0268 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $693 | $500 | Implemented |
NC0268 # 05 Y:2003 | 05 | 2003 | INSULATE BARE EQUIPMENT | $162 | $329 | Not Implemented |
NC0268 # 06 Y:2003 | 06 | 2003 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $1,012 | $300 | Not Implemented |
TN0673 # 01 Y:2000 | 01 | 2000 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,075 | $2,610 | Implemented |
TN0673 # 02 Y:2000 | 02 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $980 | $1,075 | Not Implemented |
TN0673 # 03 Y:2000 | 03 | 2000 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $715 | $1,820 | Not Implemented |
TN0673 # 04 Y:2000 | 04 | 2000 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $710 | $0 | Not Implemented |
TN0673 # 05 Y:2000 | 05 | 2000 | USE A RAG RECYCLE SERVICE | $240 | $0 | Not Implemented |
TN0673 # 06 Y:2000 | 06 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $160 | $0 | Implemented |
TN0549 # 01 Y:1995 | 01 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $890 | $1,520 | Implemented |
TN0549 # 02 Y:1995 | 02 | 1995 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,249 | $4,640 | Not Implemented |
TN0549 # 03 Y:1995 | 03 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,374 | $770 | Not Implemented |
NC0004 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,514 | $1,222 | Implemented |
NC0004 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,054 | $690 | Implemented |
NC0004 # 03 Y:1993 | 03 | 1993 | RECOVER AND REUSE COOLING WATER | $834 | $500 | Not Implemented |
NC0004 # 04 Y:1993 | 04 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $26,384 | $1,500 | Not Implemented |
NC0004 # 05 Y:1993 | 05 | 1993 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,143 | $1,100 | Not Implemented |
NC0004 # 06 Y:1993 | 06 | 1993 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,494 | $4,500 | Not Implemented |
AT0123 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,117 | $1,131 | Implemented |
AT0123 # 02 Y:1989 | 02 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,033 | $6,000 | Implemented |
AT0123 # 03 Y:1989 | 03 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $16,183 | $1,000 | Implemented |
AT0123 # 04 Y:1989 | 04 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $392 | $600 | Implemented |
AT0123 # 05 Y:1989 | 05 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $972 | $600 | Implemented |
AT0123 # 06 Y:1989 | 06 | 1989 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $709 | $0 | Not Implemented |