Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

315

matching recommendations
Reset
SIC 344 Fabricated Structural Metal Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ME0191 # 02 Y:1996 02 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,679 $600 Implemented
ME0191 # 03 Y:1996 03 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,670 $1,070 Implemented
ME0191 # 04 Y:1996 04 1996 RECOVER WASTE HEAT FROM EQUIPMENT $2,594 $1,530 Implemented
ME0191 # 05 Y:1996 05 1996 INSTALL TIMERS AND/OR THERMOSTATS $1,984 $2,400 Implemented
ME0191 # 06 Y:1996 06 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,191 $4,542 Implemented
ME0191 # 07 Y:1996 07 1996 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $848 $200 Implemented
ME0191 # 08 Y:1996 08 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $783 $1,200 Implemented
ME0191 # 09 Y:1996 09 1996 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $782 $10,247 Implemented
UL0157 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,049 $1,157 Not Implemented
UL0157 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $81 $2,160 Not Implemented
UL0157 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $951 $87 Not Implemented
UL0157 # 04 Y:1996 04 1996 RECOVER WASTE HEAT FROM EQUIPMENT $330 $230 Not Implemented
UL0157 # 05 Y:1996 05 1996 INSTALL TIMERS AND/OR THERMOSTATS $553 $200 Not Implemented
UL0157 # 06 Y:1996 06 1996 CONTRACT A WOOD PALLET RECYCLING COMPANY $10,233 $0 Not Implemented
UL0157 # 07 Y:1996 07 1996 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $1,714 $600 Not Implemented
UL0157 # 08 Y:1996 08 1996 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $11,808 $0 Not Implemented
WV0092 # 01 Y:1996 01 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,497 $4,364 Implemented
WV0092 # 02 Y:1996 02 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $888 $1,040 Implemented
WV0092 # 03 Y:1996 03 1996 USE SYNTHETIC LUBRICANT $491 $375 Not Implemented
WV0092 # 04 Y:1996 04 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $642 $45 Not Implemented
WV0092 # 05 Y:1996 05 1996 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $3,521 $3,800 Implemented
WV0092 # 06 Y:1996 06 1996 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $3,123 $2,800 Implemented
WV0092 # 07 Y:1996 07 1996 RECOVER WASTE HEAT FROM EQUIPMENT $925 $920 Not Implemented
WV0092 # 08 Y:1996 08 1996 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $2,592 $1,495 Implemented
WV0092 # 09 Y:1996 09 1996 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $2,321 $534 Implemented