Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,509
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0220 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,586 | $500 | Implemented |
LE0220 # 03 Y:2005 | 03 | 2005 | INSULATE BARE EQUIPMENT | $594 | $450 | Implemented |
LE0220 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $377 | $80 | Implemented |
LE0220 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $298 | $450 | Not Implemented |
LE0220 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,210 | $25,315 | Implemented |
SU0216 # 01 Y:2005 | 01 | 2005 | UPGRADE OBSOLETE EQUIPMENT | $3,046 | $0 | Not Implemented |
SU0216 # 02 Y:2005 | 02 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $103 | $0 | Implemented |
SU0216 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $580 | $294 | Implemented |
SU0216 # 04 Y:2005 | 04 | 2005 | USE SYNTHETIC LUBRICANT | $193 | $300 | Implemented |
SU0216 # 05 Y:2005 | 05 | 2005 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $60,060 | $134,400 | Implemented |
SU0216 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $416 | $981 | Implemented |
SU0216 # 07 Y:2005 | 07 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,140 | $3,550 | Not Implemented |
SU0216 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,013 | $17,360 | Implemented |
SU0216 # 09 Y:2005 | 09 | 2005 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $389 | $1,520 | Not Implemented |
AS0404 # 01 Y:2005 | 01 | 2005 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $60,950 | $0 | Not Implemented |
AS0404 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,578 | $45,427 | Not Implemented |
AS0404 # 03 Y:2005 | 03 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $6,521 | $11,360 | Not Implemented |
AS0404 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,338 | $3,000 | Not Implemented |
AS0404 # 05 Y:2005 | 05 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,106 | $50 | Not Implemented |
AS0404 # 06 Y:2005 | 06 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $197 | $97 | Not Implemented |
UD0722 # 01 Y:2005 | 01 | 2005 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $113,700 | $454,800 | Not Implemented |
UD0722 # 02 Y:2005 | 02 | 2005 | INSTALL OCCUPANCY SENSORS | $6,570 | $21,200 | Not Implemented |
UD0722 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,334 | $192 | Implemented |
UD0722 # 04 Y:2005 | 04 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $2,776 | $1,448 | Implemented |
UD0722 # 05 Y:2005 | 05 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,734 | $9,650 | Implemented |