Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0314 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,382 | $4,955 | Not Implemented |
BD0314 # 05 Y:2006 | 05 | 2006 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,824 | $1,200 | Not Implemented |
BD0314 # 04 Y:2006 | 04 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $7,677 | $9,600 | Not Implemented |
BD0314 # 03 Y:2006 | 03 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $491 | $1,250 | Implemented |
BD0314 # 02 Y:2006 | 02 | 2006 | USE SYNTHETIC LUBRICANT | $1,020 | $1,500 | Not Implemented |
BD0314 # 01 Y:2006 | 01 | 2006 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $9,543 | $0 | Not Implemented |
BD0314 # 07 Y:2006 | 07 | 2006 | INSTALL OCCUPANCY SENSORS | $1,221 | $525 | Not Implemented |
BD0314 # 08 Y:2006 | 08 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $421 | $1,230 | Not Implemented |
BD0298 # 01 Y:2006 | 01 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,476 | $1,014 | Implemented |
BD0298 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $350 | $350 | Implemented |
BD0298 # 04 Y:2006 | 04 | 2006 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $436 | $1,200 | Implemented |
BD0298 # 03 Y:2006 | 03 | 2006 | PAY BILLS ON TIME TO AVOID LATE FEES | $902 | $0 | Not Implemented |
BD0298 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $988 | $140 | Implemented |
BD0297 # 01 Y:2006 | 01 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $18,063 | $50,400 | Not Implemented |
BD0297 # 13 Y:2006 | 13 | 2006 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $58,145 | $9,400 | Implemented |
BD0297 # 12 Y:2006 | 12 | 2006 | RECOVER AND REUSE COOLING WATER | $42,543 | $36,180 | Implemented |
BD0297 # 11 Y:2006 | 11 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $235 | $140 | Implemented |
BD0297 # 10 Y:2006 | 10 | 2006 | INSTALL OCCUPANCY SENSORS | $422 | $600 | Implemented |
BD0297 # 09 Y:2006 | 09 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $455 | $600 | Implemented |
BD0297 # 08 Y:2006 | 08 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $688 | $0 | Implemented |
BD0297 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $812 | $1,625 | Implemented |
BD0297 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $823 | $2,975 | Implemented |
BD0297 # 05 Y:2006 | 05 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,324 | $6,150 | Implemented |
BD0297 # 04 Y:2006 | 04 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,600 | $600 | Implemented |
BD0297 # 03 Y:2006 | 03 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,740 | $2,500 | Implemented |