Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
78
matching recommendationsSIC | 344 | Fabricated Structural Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0899 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,496 | $1,342 | Implemented |
OK0899 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $506 | $594 | Implemented |
OK0899 # 02 Y:2014 | 02 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,062 | $9,740 | Implemented |
OK0899 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,648 | $3,905 | Implemented |
OK0899 # 05 Y:2014 | 05 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,508 | $140 | Not Implemented |
OK0899 # 06 Y:2014 | 06 | 2014 | USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING | $14,499 | $12,962 | Not Implemented |
AM0666 # 02 Y:2014 | 02 | 2014 | USE PHOTOCELL CONTROLS | $4,405 | $6,900 | Implemented |
AM0666 # 07 Y:2014 | 07 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $450 | $430 | Implemented |
AM0666 # 01 Y:2014 | 01 | 2014 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $10,980 | $15,030 | Implemented |
AM0666 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,860 | $4,450 | Implemented |
AM0666 # 04 Y:2014 | 04 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,308 | $3,000 | Implemented |
AM0666 # 05 Y:2014 | 05 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,230 | $1,035 | Implemented |
AM0666 # 06 Y:2014 | 06 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,330 | $11 | Implemented |
AM0666 # 08 Y:2014 | 08 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $420 | $500 | Implemented |
SD0488 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,362 | $2,700 | Implemented |
SD0488 # 01 Y:2014 | 01 | 2014 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $7,838 | $7,262 | Not Implemented |
SD0488 # 04 Y:2014 | 04 | 2014 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,681 | $6,350 | Implemented |
SD0488 # 06 Y:2014 | 06 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,195 | $3,145 | Not Implemented |
SD0488 # 05 Y:2014 | 05 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,278 | $3,660 | Not Implemented |
SD0488 # 03 Y:2014 | 03 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,081 | $14,125 | Not Implemented |
WV0494 # 01 Y:2014 | 01 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,985 | $5,400 | Not Implemented |
WV0494 # 02 Y:2014 | 02 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $10,532 | $51,000 | Implemented |
WV0494 # 10 Y:2014 | 10 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $371 | $1,411 | Implemented |
WV0494 # 05 Y:2014 | 05 | 2014 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,708 | $6,552 | Implemented |
WV0494 # 03 Y:2014 | 03 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,592 | $1,010 | Implemented |