Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
495
matching recommendationsSIC | 3441 | Fabricated Structural Metal |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0178 # 02 Y:1993 | 02 | 1993 | OPTIMIZE PLANT POWER FACTOR | $34,000 | $38,500 | Implemented |
AM0178 # 05 Y:1993 | 05 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,280 | $0 | Implemented |
OK0389 # 01 Y:1992 | 01 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,084 | $200 | Implemented |
OK0389 # 03 Y:1992 | 03 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,437 | $1,350 | Implemented |
OK0389 # 04 Y:1992 | 04 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $941 | $1,348 | Implemented |
OK0389 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $262 | $1,385 | Implemented |
SD0022 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,880 | $1,817 | Implemented |
SD0022 # 02 Y:1992 | 02 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,846 | $2,000 | Implemented |
SD0022 # 03 Y:1992 | 03 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $591 | $15 | Implemented |
SD0022 # 04 Y:1992 | 04 | 1992 | COVER OPEN TANKS | $516 | $169 | Implemented |
SD0022 # 05 Y:1992 | 05 | 1992 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $158 | $138 | Implemented |
SD0022 # 06 Y:1992 | 06 | 1992 | INSULATE BARE EQUIPMENT | $138 | $122 | Implemented |
SD0022 # 08 Y:1992 | 08 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $584 | $999 | Implemented |
SD0022 # 09 Y:1992 | 09 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,496 | $2,200 | Implemented |
SD0022 # 10 Y:1992 | 10 | 1992 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,222 | $0 | Implemented |
CO0243 # 01 Y:1992 | 01 | 1992 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,490 | $250 | Implemented |
CO0243 # 02 Y:1992 | 02 | 1992 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $11,590 | $5,500 | Implemented |
CO0243 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,100 | $230 | Implemented |
CO0243 # 04 Y:1992 | 04 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $280 | $220 | Implemented |
CO0243 # 05 Y:1992 | 05 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $230 | $590 | Implemented |
CO0243 # 06 Y:1992 | 06 | 1992 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,380 | $5,600 | Implemented |
CO0243 # 07 Y:1992 | 07 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,540 | $16,210 | Implemented |
CO0243 # 08 Y:1992 | 08 | 1992 | USE MINIMUM SAFE OVEN VENTILATION | $260 | $680 | Implemented |
CO0243 # 09 Y:1992 | 09 | 1992 | INSULATE BARE EQUIPMENT | $610 | $3,410 | Implemented |
KU0369 # 03 Y:1992 | 03 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $1,781 | $430 | Implemented |