Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,219
matching recommendationsSIC | 3443 | Fabricated Plate Work (boiler Shops) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0369 # 10 Y:2010 | 10 | 2010 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $20,730 | $17,200 | Not Implemented |
UM0357 # 01 Y:2009 | 01 | 2009 | INSTALL STORM WINDOWS AND DOORS | $88,261 | $361,980 | Implemented |
UM0357 # 02 Y:2009 | 02 | 2009 | USE RADIANT HEATER FOR SPOT HEATING | $48,733 | $25,000 | Implemented |
UM0357 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,053 | $42,818 | Implemented |
UM0357 # 04 Y:2009 | 04 | 2009 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $5,524 | $2,591 | Implemented |
UM0357 # 05 Y:2009 | 05 | 2009 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,523 | $1,359 | Implemented |
UM0357 # 06 Y:2009 | 06 | 2009 | INSTALL OCCUPANCY SENSORS | $1,466 | $4,692 | Implemented |
UM0357 # 07 Y:2009 | 07 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,875 | $7,500 | Implemented |
BD0354 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,388 | $80,292 | Not Implemented |
BD0354 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $767 | $1,100 | Not Implemented |
BD0354 # 03 Y:2009 | 03 | 2009 | INSTALL OCCUPANCY SENSORS | $685 | $1,816 | Not Implemented |
BD0354 # 04 Y:2009 | 04 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,005 | $0 | Not Implemented |
BD0354 # 05 Y:2009 | 05 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,270 | $1,500 | Not Implemented |
BD0354 # 06 Y:2009 | 06 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,132 | $3,100 | Not Implemented |
BD0354 # 07 Y:2009 | 07 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $13,322 | $2,000 | Not Implemented |
BD0354 # 08 Y:2009 | 08 | 2009 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $24,415 | $0 | Not Implemented |
OK0761 # 01 Y:2008 | 01 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,213 | $0 | Implemented |
OK0761 # 02 Y:2008 | 02 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,263 | $4,638 | Implemented |
OK0761 # 03 Y:2008 | 03 | 2008 | INSTALL OCCUPANCY SENSORS | $525 | $2,871 | Implemented |
OK0761 # 04 Y:2008 | 04 | 2008 | INSTALL SET-BACK TIMERS | $3,105 | $1,908 | Implemented |
OK0761 # 05 Y:2008 | 05 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $5,200 | $0 | Implemented |
SU0255 # 01 Y:2007 | 01 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,744 | $0 | Implemented |
SU0255 # 02 Y:2007 | 02 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,004 | $0 | Implemented |
SU0255 # 03 Y:2007 | 03 | 2007 | PAY BILLS ON TIME TO AVOID LATE FEES | $765 | $0 | Implemented |
SU0255 # 04 Y:2007 | 04 | 2007 | USE SYNTHETIC LUBRICANT | $336 | $0 | Not Implemented |