IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

44

matching recommendations
Reset
SIC 3443 Fabricated Plate Work (boiler Shops)
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0466 # 02 Y:2004 02 2004 INSTALL TIMERS AND/OR THERMOSTATS $7,059 $1,200 Not Implemented
WI0466 # 03 Y:2004 03 2004 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $4,749 $9,500 Not Implemented
WI0466 # 04 Y:2004 04 2004 USE EVAPORATION TO CONCENTRATE MATERIAL $4,435 $10,000 Not Implemented
WI0466 # 05 Y:2004 05 2004 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT $3,550 $0 Not Implemented
WI0466 # 06 Y:2004 06 2004 RECOVER WASTE HEAT FROM EQUIPMENT $1,755 $1,000 Not Implemented
WI0466 # 07 Y:2004 07 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,231 $740 Not Implemented
WI0062 # 07 Y:1989 07 1989 INSTALL STORM WINDOWS AND DOORS $959 $2,090 Not Implemented
WI0062 # 01 Y:1989 01 1989 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $12,224 $0 Not Implemented
WI0062 # 02 Y:1989 02 1989 INSTALL TIMERS AND/OR THERMOSTATS $4,059 $3,500 Implemented
WI0062 # 03 Y:1989 03 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $709 $2,290 Implemented
WI0062 # 04 Y:1989 04 1989 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,647 $0 Not Implemented
WI0062 # 05 Y:1989 05 1989 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,596 $6,000 Implemented
WI0062 # 06 Y:1989 06 1989 IMPROVE LUBRICATION PRACTICES $1,320 $0 Not Implemented
WI0032 # 06 Y:1988 06 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $5,181 $500 Not Implemented
WI0032 # 05 Y:1988 05 1988 RECOVER WASTE HEAT FROM EQUIPMENT $5,542 $3,000 Not Implemented
WI0032 # 04 Y:1988 04 1988 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,240 $0 Implemented
WI0032 # 03 Y:1988 03 1988 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $912 $0 Implemented
WI0032 # 02 Y:1988 02 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,304 $0 Implemented
WI0032 # 01 Y:1988 01 1988 IMPROVE LUBRICATION PRACTICES $31,106 $0 Not Implemented