Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
44
matching recommendationsSIC | 3443 | Fabricated Plate Work (boiler Shops) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0466 # 02 Y:2004 | 02 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $7,059 | $1,200 | Not Implemented |
WI0466 # 03 Y:2004 | 03 | 2004 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $4,749 | $9,500 | Not Implemented |
WI0466 # 04 Y:2004 | 04 | 2004 | USE EVAPORATION TO CONCENTRATE MATERIAL | $4,435 | $10,000 | Not Implemented |
WI0466 # 05 Y:2004 | 05 | 2004 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $3,550 | $0 | Not Implemented |
WI0466 # 06 Y:2004 | 06 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,755 | $1,000 | Not Implemented |
WI0466 # 07 Y:2004 | 07 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,231 | $740 | Not Implemented |
WI0062 # 07 Y:1989 | 07 | 1989 | INSTALL STORM WINDOWS AND DOORS | $959 | $2,090 | Not Implemented |
WI0062 # 01 Y:1989 | 01 | 1989 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $12,224 | $0 | Not Implemented |
WI0062 # 02 Y:1989 | 02 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $4,059 | $3,500 | Implemented |
WI0062 # 03 Y:1989 | 03 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $709 | $2,290 | Implemented |
WI0062 # 04 Y:1989 | 04 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,647 | $0 | Not Implemented |
WI0062 # 05 Y:1989 | 05 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,596 | $6,000 | Implemented |
WI0062 # 06 Y:1989 | 06 | 1989 | IMPROVE LUBRICATION PRACTICES | $1,320 | $0 | Not Implemented |
WI0032 # 06 Y:1988 | 06 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,181 | $500 | Not Implemented |
WI0032 # 05 Y:1988 | 05 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,542 | $3,000 | Not Implemented |
WI0032 # 04 Y:1988 | 04 | 1988 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,240 | $0 | Implemented |
WI0032 # 03 Y:1988 | 03 | 1988 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $912 | $0 | Implemented |
WI0032 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,304 | $0 | Implemented |
WI0032 # 01 Y:1988 | 01 | 1988 | IMPROVE LUBRICATION PRACTICES | $31,106 | $0 | Not Implemented |