Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
149
matching recommendationsSIC | 3443 | Fabricated Plate Work (boiler Shops) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0407 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $971 | $903 | Implemented |
OK0407 # 06 Y:1993 | 06 | 1993 | INSTALL SET-BACK TIMERS | $725 | $750 | Implemented |
OK0381 # 01 Y:1992 | 01 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,587 | $150 | Implemented |
OK0381 # 02 Y:1992 | 02 | 1992 | INSULATE BARE EQUIPMENT | $374 | $1,389 | Implemented |
OK0381 # 03 Y:1992 | 03 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,360 | $1,185 | Implemented |
OK0381 # 04 Y:1992 | 04 | 1992 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $13,183 | $26,505 | Not Implemented |
OK0381 # 05 Y:1992 | 05 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,694 | $0 | Not Implemented |
OK0332 # 01 Y:1990 | 01 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $1,937 | $900 | Implemented |
OK0332 # 02 Y:1990 | 02 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,898 | $0 | Not Implemented |
OK0332 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $98 | $102 | Implemented |
OK0332 # 04 Y:1990 | 04 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,747 | $1,641 | Implemented |
OK0332 # 05 Y:1990 | 05 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,085 | $0 | Implemented |
OK0332 # 06 Y:1990 | 06 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,410 | $1,070 | Implemented |
OK0253 # 01 Y:1988 | 01 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $5,363 | $1,200 | Implemented |
OK0253 # 02 Y:1988 | 02 | 1988 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,357 | $0 | Implemented |
OK0253 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $225 | $57 | Not Implemented |
OK0253 # 04 Y:1988 | 04 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $83 | $159 | Not Implemented |
OK0253 # 05 Y:1988 | 05 | 1988 | USE RADIANT HEATER FOR SPOT HEATING | $4,721 | $13,000 | Implemented |
OK0253 # 06 Y:1988 | 06 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,613 | $0 | Implemented |
OK0253 # 07 Y:1988 | 07 | 1988 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,319 | $0 | Not Implemented |
OK0253 # 08 Y:1988 | 08 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $44 | $88 | Implemented |
OK0243 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,869 | $7,200 | Not Implemented |
OK0243 # 02 Y:1988 | 02 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,185 | $0 | Implemented |
OK0243 # 03 Y:1988 | 03 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $101 | $150 | Implemented |
OK0243 # 04 Y:1988 | 04 | 1988 | INSULATE BARE EQUIPMENT | $249 | $294 | Not Implemented |