Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

38

matching recommendations
Reset
SIC 3443 Fabricated Plate Work (boiler Shops)
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0332 # 05 Y:1990 05 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,085 $0 Implemented
OK0332 # 03 Y:1990 03 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $98 $102 Implemented
OK0332 # 01 Y:1990 01 1990 INSTALL TIMERS AND/OR THERMOSTATS $1,937 $900 Implemented
OK0332 # 04 Y:1990 04 1990 RECOVER WASTE HEAT FROM EQUIPMENT $7,747 $1,641 Implemented
OK0332 # 06 Y:1990 06 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,410 $1,070 Implemented
OK0332 # 02 Y:1990 02 1990 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,898 $0 Not Implemented
AM0104 # 01 Y:1990 01 1990 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,160 $10,750 Not Implemented
AM0104 # 08 Y:1990 08 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $129 $99 Not Implemented
AM0104 # 07 Y:1990 07 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,100 $128 Not Implemented
AM0104 # 06 Y:1990 06 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,400 $0 Not Implemented
AM0104 # 05 Y:1990 05 1990 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $2,900 $10,000 Not Implemented
AM0104 # 04 Y:1990 04 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,100 $660 Not Implemented
AM0104 # 03 Y:1990 03 1990 RECOVER WASTE HEAT FROM EQUIPMENT $3,600 $1,800 Not Implemented
AM0104 # 02 Y:1990 02 1990 OPTIMIZE PLANT POWER FACTOR $4,050 $4,800 Not Implemented
MA0182 # 06 Y:1990 06 1990 REDUCE VENTILATION AIR $2,509 $500 Not Implemented
MA0182 # 01 Y:1990 01 1990 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $5,921 $116,600 Implemented
MA0182 # 02 Y:1990 02 1990 INSTALL SET-BACK TIMERS $368 $440 Implemented
MA0182 # 03 Y:1990 03 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $678 $336 Implemented
MA0182 # 04 Y:1990 04 1990 INSULATE BARE EQUIPMENT $644 $1,540 Not Implemented
MA0182 # 05 Y:1990 05 1990 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $471 $675 Implemented
AM0084 # 07 Y:1990 07 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $90 $0 Implemented
AM0084 # 06 Y:1990 06 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $105 $0 Implemented
AM0084 # 05 Y:1990 05 1990 INSTALL SET-BACK TIMERS $270 $0 Implemented
AM0084 # 04 Y:1990 04 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $282 $606 Implemented
AM0084 # 01 Y:1990 01 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,755 $1,000 Implemented