Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

64

matching recommendations
Reset
SIC 3444 Sheet Metalwork
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
BD0430 # 06 Y:2013 06 2013 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $278 $600 Not Implemented
BD0430 # 07 Y:2013 07 2013 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL $4,500 $10,000 Implemented
BD0430 # 05 Y:2013 05 2013 INSTALL OCCUPANCY SENSORS $397 $200 Not Implemented
BD0430 # 04 Y:2013 04 2013 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $741 $25 Not Implemented
BD0430 # 01 Y:2013 01 2013 USE RADIANT HEATER FOR SPOT HEATING $7,450 $22,500 Not Implemented
BD0430 # 03 Y:2013 03 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,001 $3,520 Not Implemented
BD0430 # 02 Y:2013 02 2013 USE PHOTOCELL CONTROLS $2,289 $200 Not Implemented
BD0314 # 08 Y:2006 08 2006 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $421 $1,230 Not Implemented
BD0314 # 07 Y:2006 07 2006 INSTALL OCCUPANCY SENSORS $1,221 $525 Not Implemented
BD0314 # 06 Y:2006 06 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,382 $4,955 Not Implemented
BD0314 # 05 Y:2006 05 2006 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $1,824 $1,200 Not Implemented
BD0314 # 04 Y:2006 04 2006 USE RADIANT HEATER FOR SPOT HEATING $7,677 $9,600 Not Implemented
BD0314 # 03 Y:2006 03 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $491 $1,250 Implemented
BD0314 # 02 Y:2006 02 2006 USE SYNTHETIC LUBRICANT $1,020 $1,500 Not Implemented
BD0314 # 01 Y:2006 01 2006 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $9,543 $0 Not Implemented
BD0124 # 07 Y:1998 07 1998 MINIMIZE WATER USAGE $319 $625 Not Implemented
BD0124 # 01 Y:1998 01 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,996 $900 Implemented
BD0124 # 10 Y:1998 10 1998 PAY BILLS ON TIME TO AVOID LATE FEES $263 $0 Not Implemented
BD0124 # 09 Y:1998 09 1998 RECOVER AND REUSE WASTE MATERIAL $5,715 $2,500 Implemented
BD0124 # 08 Y:1998 08 1998 MOVE PRODUCT USING MECHANICAL MEANS $11,232 $6,000 Not Implemented
BD0124 # 06 Y:1998 06 1998 INSTALL OCCUPANCY SENSORS $459 $225 Not Implemented
BD0124 # 05 Y:1998 05 1998 USE SYNTHETIC LUBRICANT $641 $300 Not Implemented
BD0124 # 04 Y:1998 04 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $647 $250 Not Implemented
BD0124 # 03 Y:1998 03 1998 UPGRADE CONTROLS ON COMPRESSORS $2,025 $0 Implemented
BD0124 # 02 Y:1998 02 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,869 $4,085 Implemented