Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,512

matching recommendations
Reset
SIC 3444 Sheet Metalwork
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KG0042 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,779 $10,990 Not Implemented
KG0042 # 02 Y:1995 02 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,293 $160 Implemented
KG0042 # 03 Y:1995 03 1995 USE SYNTHETIC LUBRICANT $2,596 $0 Implemented
KG0042 # 04 Y:1995 04 1995 INSTALL TIMERS AND/OR THERMOSTATS $1,424 $300 Implemented
KG0042 # 05 Y:1995 05 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,086 $2,408 Not Implemented
KG0042 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $708 $153 Implemented
UF0125 # 01 Y:1995 01 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,471 $0 Not Implemented
UF0125 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $190 $71 Implemented
UF0125 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $152 $360 Not Implemented
UF0125 # 04 Y:1995 04 1995 REDESIGN PROCESS $14,920 $19,775 Not Implemented
UF0125 # 05 Y:1995 05 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $307 $966 Implemented
UF0125 # 06 Y:1995 06 1995 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $114 $250 Implemented
UF0129 # 01 Y:1995 01 1995 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $115 $0 Implemented
UF0129 # 02 Y:1995 02 1995 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $8,692 $0 Not Implemented
UF0129 # 03 Y:1995 03 1995 USE PHOTOCELL CONTROLS $3,673 $5,400 Implemented
UF0129 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,653 $586 Implemented
UF0129 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,363 $2,828 Implemented
UF0129 # 06 Y:1995 06 1995 INSTALL OCCUPANCY SENSORS $379 $666 Not Implemented
UF0129 # 07 Y:1995 07 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $952 $1,780 Implemented
UF0129 # 08 Y:1995 08 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $269 $775 Not Implemented
UF0129 # 09 Y:1995 09 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $200 $280 Not Implemented
UF0129 # 10 Y:1995 10 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,475 $1,000 Implemented
AS0158 # 01 Y:1995 01 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $19,900 $2,900 Implemented
AS0158 # 02 Y:1995 02 1995 USE SYNTHETIC LUBRICANT $4,212 $2,834 Not Implemented
AS0158 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $855 $200 Not Implemented