Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,512
matching recommendationsSIC | 3444 | Sheet Metalwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0003 # 03 Y:1994 | 03 | 1994 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,799 | $140 | Implemented |
BD0003 # 04 Y:1994 | 04 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $399 | $0 | Implemented |
BD0003 # 05 Y:1994 | 05 | 1994 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $67 | $20 | Not Implemented |
BD0003 # 06 Y:1994 | 06 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,292 | $0 | Implemented |
BD0003 # 07 Y:1994 | 07 | 1994 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $386 | $250 | Implemented |
AS0110 # 01 Y:1994 | 01 | 1994 | INSTALL OCCUPANCY SENSORS | $2,711 | $8,203 | Implemented |
AS0110 # 02 Y:1994 | 02 | 1994 | USE PHOTOCELL CONTROLS | $142 | $450 | Implemented |
AS0110 # 03 Y:1994 | 03 | 1994 | USE PHOTOCELL CONTROLS | $646 | $90 | Not Implemented |
AS0110 # 04 Y:1994 | 04 | 1994 | INSTALL SET-BACK TIMERS | $676 | $100 | Implemented |
AS0110 # 05 Y:1994 | 05 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $205 | $400 | Not Implemented |
AS0110 # 06 Y:1994 | 06 | 1994 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $151 | $758 | Not Implemented |
AS0110 # 07 Y:1994 | 07 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $965 | $400 | Implemented |
AS0109 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,756 | $825 | Implemented |
AS0109 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,292 | $1,342 | Implemented |
AS0109 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $546 | $500 | Not Implemented |
AS0109 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,997 | $585 | Implemented |
AS0109 # 05 Y:1994 | 05 | 1994 | INSTALL OCCUPANCY SENSORS | $7,611 | $26,535 | Not Implemented |
AS0109 # 06 Y:1994 | 06 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $374 | $2,060 | Implemented |
KU0409 # 01 Y:1993 | 01 | 1993 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,324 | $264 | Implemented |
KU0409 # 02 Y:1993 | 02 | 1993 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $407 | $0 | Implemented |
KU0409 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $476 | $2,430 | Implemented |
KU0409 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $382 | $559 | Implemented |
KU0409 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $346 | $410 | Implemented |
KU0409 # 06 Y:1993 | 06 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $104 | $30 | Implemented |
ND0161 # 01 Y:1993 | 01 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,842 | $840 | Implemented |