Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
166
matching recommendationsSIC | 3444 | Sheet Metalwork |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0247 # 02 Y:2000 | 02 | 2000 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,905 | $3,000 | Not Implemented |
SD0247 # 03 Y:2000 | 03 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,007 | $0 | Not Implemented |
SD0247 # 04 Y:2000 | 04 | 2000 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $5,628 | $3,000 | Not Implemented |
SD0247 # 05 Y:2000 | 05 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,279 | $1,800 | Not Implemented |
SD0247 # 06 Y:2000 | 06 | 2000 | INSULATE BARE EQUIPMENT | $570 | $1,030 | Not Implemented |
SD0247 # 07 Y:2000 | 07 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,440 | $12,500 | Not Implemented |
SD0247 # 08 Y:2000 | 08 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $6,916 | $0 | Not Implemented |
SD0247 # 09 Y:2000 | 09 | 2000 | IMPROVE SPACE COMFORT CONDITIONING | $32,000 | $10,380 | Not Implemented |
SD0242 # 01 Y:2000 | 01 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $14,399 | $1,960 | Implemented |
SD0242 # 02 Y:2000 | 02 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,283 | $3,000 | Not Implemented |
SD0242 # 03 Y:2000 | 03 | 2000 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,568 | $0 | Not Implemented |
SD0242 # 04 Y:2000 | 04 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,903 | $0 | Implemented |
SD0242 # 05 Y:2000 | 05 | 2000 | CONVERT TO ELECTROSTATIC POWDER COATING | $42,700 | $58,000 | Not Implemented |
SD0242 # 06 Y:2000 | 06 | 2000 | CONVERT TO AQUEOUS CLEANING SYSTEM | $8,347 | $0 | Not Implemented |
SD0242 # 07 Y:2000 | 07 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,533 | $8,500 | Implemented |
SD0242 # 08 Y:2000 | 08 | 2000 | RECYCLE WHITE WATER | $313 | $400 | Not Implemented |
SD0242 # 09 Y:2000 | 09 | 2000 | USE ONLY AMOUNT OF PACKAGING MATERIAL NECESSARY | $2,431 | $3,294 | Not Implemented |
SF0180 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,071 | $0 | Implemented |
SF0180 # 02 Y:1999 | 02 | 1999 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,639 | $0 | Not Implemented |
SF0180 # 03 Y:1999 | 03 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,900 | $0 | Implemented |
SF0180 # 04 Y:1999 | 04 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $245 | $0 | Implemented |
SF0180 # 05 Y:1999 | 05 | 1999 | USE PHOTOCELL CONTROLS | $3,661 | $2,340 | Implemented |
SF0180 # 06 Y:1999 | 06 | 1999 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $777 | $1,087 | Implemented |
SF0180 # 07 Y:1999 | 07 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $757 | $1,133 | Implemented |
SF0180 # 08 Y:1999 | 08 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $303 | $644 | Implemented |