IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,045

matching recommendations
Reset
SIC 345 Screw Machine Products, Bolts, Etc.
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0317 # 01 Y:1998 01 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,682 $1,342 Not Implemented
WI0317 # 02 Y:1998 02 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $986 $0 Not Implemented
WI0317 # 03 Y:1998 03 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $597 $2,250 Not Implemented
WI0317 # 04 Y:1998 04 1998 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES $1,611 $0 Implemented
WI0317 # 05 Y:1998 05 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,138 $740 Not Implemented
WI0317 # 06 Y:1998 06 1998 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $794 $0 Implemented
WI0317 # 07 Y:1998 07 1998 REPLACE CLOTH RAGS WITH PAPER TOWELS $400 $0 Not Implemented
UM0090 # 06 Y:1997 06 1997 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES $19,843 $14,648 Not Implemented
UM0090 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,096 $1,755 Implemented
UM0090 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,710 $4,546 Implemented
UM0090 # 03 Y:1997 03 1997 INSTALL OCCUPANCY SENSORS $113 $200 Not Implemented
UM0090 # 04 Y:1997 04 1997 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $1,141 $2,000 Implemented
UM0090 # 05 Y:1997 05 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $5,250 $0 Implemented
UM0066 # 01 Y:1996 01 1996 OPTIMIZE PLANT POWER FACTOR $9,433 $6,541 Not Implemented
UM0066 # 02 Y:1996 02 1996 INSULATE BARE EQUIPMENT $256 $990 Not Implemented
UM0066 # 03 Y:1996 03 1996 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $8,215 $39,138 Not Implemented
UM0066 # 04 Y:1996 04 1996 USE "WASH-LESS" PROCESSING EQUIPMENT $14,491 $11,000 Not Implemented
ND0240 # 01 Y:1996 01 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,400 $750 Not Implemented
ND0240 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $23,589 $18,280 Implemented
ND0240 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $544 $1,100 Not Implemented
ND0240 # 04 Y:1996 04 1996 PAY UTILITY BILLS ON TIME $15 $0 Not Implemented
ND0240 # 05 Y:1996 05 1996 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $132 $250 Not Implemented
ND0240 # 06 Y:1996 06 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $270 $1,008 Not Implemented
ND0240 # 07 Y:1996 07 1996 OPTIMIZE PLANT POWER FACTOR $7,294 $12,852 Implemented
SD0141 # 01 Y:1996 01 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $5,869 $13,500 Not Implemented