Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
81
matching recommendationsSIC | 346 | Metal Forgings And Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0064 # 07 Y:2011 | 07 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $37,600 | $5,500 | Implemented |
TT0064 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,844 | $29,100 | Implemented |
TT0064 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,600 | $2,500 | Implemented |
TT0064 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,400 | $26,700 | Implemented |
TT0064 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $957 | $4,000 | Implemented |
TT0048 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,400 | $4,500 | Not Implemented |
TT0048 # 01 Y:2010 | 01 | 2010 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $56,000 | $1,000 | Implemented |
TT0048 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $97,000 | $421,000 | Not Implemented |
TT0048 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,900 | $91,150 | Not Implemented |
TT0048 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,500 | $4,500 | Not Implemented |
AR0182 # 07 Y:2000 | 07 | 2000 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $222,939 | $244,000 | Not Implemented |
AR0182 # 06 Y:2000 | 06 | 2000 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $4,468 | $175 | Implemented |
AR0182 # 05 Y:2000 | 05 | 2000 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $60,765 | $150,000 | Implemented |
AR0182 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,868 | $130 | Implemented |
AR0182 # 03 Y:2000 | 03 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $496 | $180 | Not Implemented |
AR0182 # 02 Y:2000 | 02 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $351 | $0 | Implemented |
AR0182 # 01 Y:2000 | 01 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $916 | $1,360 | Not Implemented |
TN0641 # 01 Y:1998 | 01 | 1998 | MOVE PRODUCT USING MECHANICAL MEANS | $462,700 | $440,300 | Not Implemented |
TN0641 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,810 | $5,000 | Implemented |
TN0641 # 03 Y:1998 | 03 | 1998 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $3,560 | $2,500 | Implemented |
TN0641 # 04 Y:1998 | 04 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,130 | $980 | Implemented |
TN0641 # 05 Y:1998 | 05 | 1998 | USE OPTIMUM THICKNESS INSULATION | $240 | $550 | Not Implemented |
TN0641 # 06 Y:1998 | 06 | 1998 | USE A RAG RECYCLE SERVICE | $140 | $0 | Not Implemented |
TN0538 # 04 Y:1995 | 04 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $471 | $810 | Not Implemented |
TN0538 # 05 Y:1995 | 05 | 1995 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $218 | $435 | Not Implemented |