Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsSIC | 346 | Metal Forgings And Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0005 # 02 Y:1984 | 02 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $314 | $0 | Implemented |
MA0005 # 03 Y:1984 | 03 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,993 | $200 | Implemented |
MA0005 # 04 Y:1984 | 04 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $64,789 | $140,000 | Not Implemented |
MA0005 # 05 Y:1984 | 05 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $22,212 | $0 | Implemented |
MA0005 # 01 Y:1984 | 01 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $553 | $62 | Implemented |
ST0002 # 07 Y:1984 | 07 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $584 | $420 | Implemented |
ST0002 # 12 Y:1984 | 12 | 1984 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,070 | $0 | Implemented |
ST0002 # 11 Y:1984 | 11 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $147 | $370 | Implemented |
ST0002 # 10 Y:1984 | 10 | 1984 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $296 | $0 | Implemented |
ST0002 # 09 Y:1984 | 09 | 1984 | INSTALL AUTOMATIC STACK DAMPER | $564 | $282 | Not Implemented |
ST0002 # 08 Y:1984 | 08 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,455 | $1,800 | Implemented |
ST0002 # 06 Y:1984 | 06 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $450 | $537 | Implemented |
ST0002 # 05 Y:1984 | 05 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $386 | $182 | Not Implemented |
ST0002 # 04 Y:1984 | 04 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,150 | $310 | Implemented |
ST0002 # 03 Y:1984 | 03 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $845 | $80 | Implemented |
ST0002 # 02 Y:1984 | 02 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,941 | $40 | Implemented |
ST0002 # 01 Y:1984 | 01 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $306 | $0 | Implemented |
UD0131 # 01 Y:1984 | 01 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,171 | $0 | Implemented |
UD0131 # 02 Y:1984 | 02 | 1984 | REDUCE GLAZED AREAS IN BUILDINGS | $17,464 | $50,000 | Implemented |
UD0131 # 03 Y:1984 | 03 | 1984 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $3,070 | $8,000 | Implemented |
UD0131 # 04 Y:1984 | 04 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,853 | $800 | Implemented |
UD0131 # 05 Y:1984 | 05 | 1984 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $2,576 | $4,000 | Implemented |
UD0131 # 06 Y:1984 | 06 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,453 | $20,000 | Implemented |