Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

718

matching recommendations
Reset
SIC 3462 Iron And Steel Forgings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0218 # 02 Y:1987 02 1987 RECOVER WASTE HEAT FROM EQUIPMENT $3,039 $9,500 Not Implemented
UD0218 # 03 Y:1987 03 1987 TURN OFF EQUIPMENT WHEN NOT IN USE $463 $129 Not Implemented
UD0218 # 04 Y:1987 04 1987 USE DEMAND CONTROLLER OR LOAD SHEDDER $11,481 $0 Implemented
LT0025 # 01 Y:1985 01 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $154 $300 Implemented
LT0025 # 02 Y:1985 02 1985 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $537 $670 Implemented
LT0025 # 03 Y:1985 03 1985 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $6,134 $500 Implemented
LT0025 # 04 Y:1985 04 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $531 $400 Implemented
MA0005 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $553 $62 Implemented
MA0005 # 02 Y:1984 02 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $314 $0 Implemented
MA0005 # 03 Y:1984 03 1984 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,993 $200 Implemented
MA0005 # 04 Y:1984 04 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $64,789 $140,000 Not Implemented
MA0005 # 05 Y:1984 05 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $22,212 $0 Implemented
UD0056 # 01 Y:1982 01 1982 INSTALL STORM WINDOWS AND DOORS $773 $600 Not Implemented
UD0056 # 02 Y:1982 02 1982 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $232,119 $517,000 Not Implemented
UD0056 # 03 Y:1982 03 1982 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $13,145 $517,000 Not Implemented
UD0052 # 01 Y:1982 01 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,538 $900 Not Implemented
UD0052 # 02 Y:1982 02 1982 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $182,775 $87,000 Not Implemented
UD0052 # 03 Y:1982 03 1982 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $27,811 $0 Not Implemented