Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
642
matching recommendationsSIC | 3465 | Automotive Stampings |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UK1501 # 11 Y:2015 | 11 | 2015 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,021 | $9,364 | Not Implemented |
UK1501 # 12 Y:2015 | 12 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $270 | $510 | Not Implemented |
UK1501 # 13 Y:2015 | 13 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $10,309 | $0 | Not Implemented |
UK1501 # 14 Y:2015 | 14 | 2015 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $17,085 | $1,000 | Implemented |
UD0920 # 01 Y:2015 | 01 | 2015 | COMBINE UTILITY METERS | $13,359 | $0 | Implemented |
UD0920 # 02 Y:2015 | 02 | 2015 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $1,749 | $0 | Not Implemented |
UD0920 # 03 Y:2015 | 03 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $3,626 | $200 | Not Implemented |
UD0920 # 04 Y:2015 | 04 | 2015 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,654 | $600 | Not Implemented |
UD0920 # 05 Y:2015 | 05 | 2015 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,374 | $0 | Not Implemented |
UD0920 # 06 Y:2015 | 06 | 2015 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $47,012 | $0 | Not Implemented |
UD0920 # 07 Y:2015 | 07 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $21,116 | $0 | Not Implemented |
UD0920 # 08 Y:2015 | 08 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,293 | $25,800 | Not Implemented |
UD0920 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,453 | $20,680 | Not Implemented |
UD0920 # 10 Y:2015 | 10 | 2015 | INSTALL OCCUPANCY SENSORS | $1,355 | $3,835 | Not Implemented |
UD0920 # 11 Y:2015 | 11 | 2015 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $11,244 | $0 | Not Implemented |
UD0920 # 12 Y:2015 | 12 | 2015 | CONVERT TO AQUEOUS CLEANING SYSTEM | $6,095 | $7,375 | Implemented |
UM0453 # 02 Y:2015 | 02 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,831 | $1,000 | Implemented |
UM0453 # 01 Y:2015 | 01 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $19,380 | $5,000 | Not Implemented |
UM0453 # 03 Y:2015 | 03 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,442 | $1,500 | Implemented |
UM0453 # 04 Y:2015 | 04 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,115 | $5,400 | Not Implemented |
UM0453 # 05 Y:2015 | 05 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,852 | $4,000 | Implemented |
UM0451 # 01 Y:2014 | 01 | 2014 | OPTIMIZE PLANT POWER FACTOR | $16,165 | $25,000 | Implemented |
UM0451 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $6,320 | $4,800 | Implemented |
UM0451 # 03 Y:2014 | 03 | 2014 | REVISE SMOKE CLEANUP FROM OPERATIONS | $79,670 | $60,000 | Not Implemented |
UM0451 # 04 Y:2014 | 04 | 2014 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,930 | $6,000 | Not Implemented |