Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

30

matching recommendations
Reset
SIC 3465 Automotive Stampings
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0200 # 03 Y:2017 03 2017 RECOVER WASTE HEAT FROM EQUIPMENT $6,931 $15,000 Not Implemented
TT0200 # 02 Y:2017 02 2017 INSTALL TIMERS AND/OR THERMOSTATS $9,558 $46,250 Implemented
TT0200 # 01 Y:2017 01 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $9,941 $3,050 Not Implemented
TT0200 # 06 Y:2017 06 2017 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $2,216 $7,500 Not Implemented
TT0200 # 05 Y:2017 05 2017 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,708 $63 Not Implemented
TT0200 # 04 Y:2017 04 2017 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $3,952 $15,000 Not Implemented
TT0200 # 07 Y:2017 07 2017 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,772 $1,000 Implemented
TT0135 # 04 Y:2014 04 2014 APPLY FOR INVESTMENT INCENTIVES $31,797 $5,000 Implemented
TT0135 # 03 Y:2014 03 2014 DISCONNECT BALLASTS $351 $0 Not Implemented
TT0135 # 02 Y:2014 02 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,172 $3,000 Implemented
TT0135 # 01 Y:2014 01 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,394 $100 Implemented
TT0091 # 04 Y:2012 04 2012 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $3,203 $0 Implemented
TT0091 # 03 Y:2012 03 2012 INSTALL OCCUPANCY SENSORS $688 $350 Implemented
TT0091 # 02 Y:2012 02 2012 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $170 $20 Not Implemented
TT0091 # 01 Y:2012 01 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,974 $3,000 Implemented
TT0048 # 04 Y:2010 04 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $18,500 $4,500 Not Implemented
TT0048 # 05 Y:2010 05 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,400 $4,500 Not Implemented
TT0048 # 03 Y:2010 03 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $35,900 $91,150 Not Implemented
TT0048 # 02 Y:2010 02 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $97,000 $421,000 Not Implemented
TT0048 # 01 Y:2010 01 2010 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $56,000 $1,000 Implemented
TN0324 # 08 Y:1987 08 1987 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $822 $1,360 Implemented
TN0324 # 06 Y:1987 06 1987 ADJUST VENTS TO MINIMIZE ENERGY USE $967 $0 Implemented
TN0324 # 05 Y:1987 05 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,322 $1,120 Implemented
TN0324 # 04 Y:1987 04 1987 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,386 $2,836 Not Implemented
TN0324 # 03 Y:1987 03 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,612 $4,800 Implemented