Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
967
matching recommendationsSIC | 3469 | Metal Stampings, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0660 # 08 Y:2003 | 08 | 2003 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $5,026 | $8,400 | Implemented |
UD0660 # 09 Y:2003 | 09 | 2003 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $3,983 | $14,150 | Not Implemented |
UD0660 # 10 Y:2003 | 10 | 2003 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $3,648 | $0 | Not Implemented |
UD0660 # 11 Y:2003 | 11 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,905 | $7,338 | Not Implemented |
UD0660 # 12 Y:2003 | 12 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,763 | $3,318 | Implemented |
UD0660 # 13 Y:2003 | 13 | 2003 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $2,019 | $4,158 | Not Implemented |
UD0660 # 14 Y:2003 | 14 | 2003 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $1,707 | $0 | Not Implemented |
UD0660 # 15 Y:2003 | 15 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,443 | $1,000 | Implemented |
UD0660 # 16 Y:2003 | 16 | 2003 | ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF | $1,260 | $0 | Implemented |
UD0660 # 17 Y:2003 | 17 | 2003 | INSTALL OCCUPANCY SENSORS | $1,080 | $4,200 | Not Implemented |
UD0660 # 18 Y:2003 | 18 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $946 | $2,442 | Not Implemented |
UD0660 # 19 Y:2003 | 19 | 2003 | INSTALL OCCUPANCY SENSORS | $256 | $167 | Not Implemented |
UD0660 # 20 Y:2003 | 20 | 2003 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $150 | $0 | Implemented |
OK0653 # 01 Y:2003 | 01 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,530 | $6,844 | Not Implemented |
OK0653 # 02 Y:2003 | 02 | 2003 | USE OPTIMUM THICKNESS INSULATION | $14,697 | $8,210 | Implemented |
OK0653 # 03 Y:2003 | 03 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,582 | $600 | Not Implemented |
OK0653 # 04 Y:2003 | 04 | 2003 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,904 | $13,860 | Not Implemented |
OK0653 # 05 Y:2003 | 05 | 2003 | INSTALL SET-BACK TIMERS | $5,337 | $3,280 | Not Implemented |
OK0653 # 06 Y:2003 | 06 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $25,432 | $4,800 | Not Implemented |
OK0653 # 07 Y:2003 | 07 | 2003 | AUTOMATE FINISHING PROCESS | $36,680 | $73,250 | Not Implemented |
UD0649 # 01 Y:2002 | 01 | 2002 | ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS | $72,080 | $3,600 | Not Implemented |
UD0649 # 02 Y:2002 | 02 | 2002 | EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME | $16,650 | $15,000 | Not Implemented |
UD0649 # 03 Y:2002 | 03 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,835 | $3,500 | Not Implemented |
UD0649 # 04 Y:2002 | 04 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,660 | $6,691 | Implemented |
UD0649 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,306 | $6,000 | Implemented |