Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
967
matching recommendationsSIC | 3469 | Metal Stampings, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0083 # 09 Y:1997 | 09 | 1997 | RECOVER AND REUSE COOLING WATER | $10,457 | $10,250 | Not Implemented |
BD0083 # 10 Y:1997 | 10 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,653 | $750 | Not Implemented |
BD0083 # 11 Y:1997 | 11 | 1997 | MINIMIZE WATER USAGE | $642 | $875 | Not Implemented |
BD0083 # 12 Y:1997 | 12 | 1997 | INSTALL SENSORS TO DETECT DEFECTS | $2,600 | $725 | Implemented |
NV0078 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $878 | $54 | Not Implemented |
NV0078 # 02 Y:1997 | 02 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $7,471 | $2,850 | Not Implemented |
NV0078 # 03 Y:1997 | 03 | 1997 | INSTALL OCCUPANCY SENSORS | $146 | $186 | Implemented |
NV0078 # 04 Y:1997 | 04 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $310 | $360 | Not Implemented |
NV0078 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $691 | $70 | Not Implemented |
NV0078 # 06 Y:1997 | 06 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,156 | $400 | Implemented |
NV0078 # 07 Y:1997 | 07 | 1997 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $645 | $589 | Implemented |
NV0078 # 08 Y:1997 | 08 | 1997 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $111,690 | $110,000 | Implemented |
NV0078 # 09 Y:1997 | 09 | 1997 | ADOPT IN-HOUSE MATERIAL GENERATION | $60,000 | $50,000 | Not Implemented |
NV0078 # 10 Y:1997 | 10 | 1997 | PAY BILLS ON TIME TO AVOID LATE FEES | $438 | $0 | Implemented |
NV0078 # 11 Y:1997 | 11 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $3,600 | $300 | Not Implemented |
NV0078 # 12 Y:1997 | 12 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $1,200 | $0 | Implemented |
BD0080 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,382 | $8,810 | Not Implemented |
BD0080 # 02 Y:1997 | 02 | 1997 | COMBINE UTILITY METERS | $2,671 | $100 | Not Implemented |
BD0080 # 03 Y:1997 | 03 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,361 | $1,000 | Not Implemented |
BD0080 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,034 | $3,504 | Implemented |
BD0080 # 05 Y:1997 | 05 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $901 | $800 | Not Implemented |
BD0080 # 06 Y:1997 | 06 | 1997 | INSTALL OCCUPANCY SENSORS | $703 | $900 | Implemented |
BD0080 # 07 Y:1997 | 07 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $422 | $450 | Implemented |
BD0080 # 08 Y:1997 | 08 | 1997 | INSTALL FLOATING COVERS ON TANKS OF VOLATILE MATERIALS TO REDUCE EVAPORATION | $2,430 | $400 | Implemented |
BD0080 # 09 Y:1997 | 09 | 1997 | MINIMIZE WATER USAGE | $469 | $1,265 | Not Implemented |