Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

265

matching recommendations
Reset
SIC 347 Metal Services, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0061 # 02 Y:1995 02 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $129 $170 Implemented
SF0061 # 03 Y:1995 03 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $347 $1,570 Not Implemented
SF0061 # 04 Y:1995 04 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $1,658 $2,208 Implemented
SF0061 # 05 Y:1995 05 1995 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $733 $1,300 Not Implemented
SF0061 # 06 Y:1995 06 1995 COVER OPEN TANKS $3,373 $1,560 Not Implemented
SF0061 # 07 Y:1995 07 1995 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE $6,048 $2,955 Not Implemented
SF0061 # 08 Y:1995 08 1995 USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE $2,880 $25,300 Not Implemented
SF0061 # 09 Y:1995 09 1995 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $7,532 $1,288 Implemented
SF0061 # 10 Y:1995 10 1995 TREAT AND REUSE RINSE WATERS $10,340 $6,344 Not Implemented
SD0097 # 01 Y:1994 01 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $613 $300 Implemented
SD0097 # 02 Y:1994 02 1994 INSULATE BARE EQUIPMENT $746 $1,350 Not Implemented
SD0097 # 03 Y:1994 03 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $336 $353 Not Implemented
SD0097 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,480 $3,045 Implemented
SD0097 # 05 Y:1994 05 1994 INSTALL SPECTRAL REFLECTORS / DELAMP $1,331 $2,205 Implemented
SD0097 # 06 Y:1994 06 1994 INSTALL SPECTRAL REFLECTORS / DELAMP $439 $560 Not Implemented
SD0097 # 07 Y:1994 07 1994 INSTALL OCCUPANCY SENSORS $3,008 $3,515 Not Implemented
SD0097 # 08 Y:1994 08 1994 USE PHOTOCELL CONTROLS $307 $425 Not Implemented
SD0097 # 09 Y:1994 09 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $232 $165 Not Implemented
SF0019 # 01 Y:1994 01 1994 USE POWER DURING OFF-PEAK PERIODS $6,225 $4,000 Implemented
SF0019 # 02 Y:1994 02 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,939 $800 Implemented
SF0019 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,685 $400 Implemented
SF0019 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,026 $1,671 Implemented
SF0019 # 05 Y:1994 05 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $796 $348 Not Implemented
SF0019 # 06 Y:1994 06 1994 INSULATE BARE EQUIPMENT $384 $745 Implemented
SD0066 # 01 Y:1993 01 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,693 $507 Implemented