ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0371 # 01 Y:2008 | 01 | 2008 | ADJUST BURNERS FOR EFFICIENT OPERATION | $284,875 | $10,157 | Implemented |
WV0371 # 02 Y:2008 | 02 | 2008 | ADJUST BURNERS FOR EFFICIENT OPERATION | $249,839 | $8,000 | Not Implemented |
WV0371 # 03 Y:2008 | 03 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $179,387 | $235,000 | Implemented |
WV0371 # 04 Y:2008 | 04 | 2008 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $42,970 | $2,500 | Implemented |
WV0371 # 05 Y:2008 | 05 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $29,665 | $1,823 | Implemented |
WV0371 # 07 Y:2008 | 07 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $16,829 | $2,310 | Implemented |
WV0371 # 08 Y:2008 | 08 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $14,852 | $2,980 | Implemented |
WV0371 # 09 Y:2008 | 09 | 2008 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $13,433 | $3,500 | Implemented |
WV0371 # 10 Y:2008 | 10 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,725 | $683 | Implemented |
WV0371 # 11 Y:2008 | 11 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,269 | $530 | Implemented |
WV0323 # 02 Y:2005 | 02 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,842 | $0 | Not Implemented |
WV0323 # 01 Y:2005 | 01 | 2005 | INSULATE BARE EQUIPMENT | $12,908 | $363 | Not Implemented |
WV0323 # 03 Y:2005 | 03 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,575 | $1,000 | Not Implemented |
WV0323 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,232 | $0 | Not Implemented |
WV0323 # 05 Y:2005 | 05 | 2005 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,033 | $1,200 | Not Implemented |
WV0323 # 06 Y:2005 | 06 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,015 | $0 | Not Implemented |
WV0323 # 07 Y:2005 | 07 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $869 | $990 | Not Implemented |
WV0323 # 08 Y:2005 | 08 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $698 | $260 | Not Implemented |
WV0323 # 09 Y:2005 | 09 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $613 | $250 | Not Implemented |
WV0323 # 10 Y:2005 | 10 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $600 | $40 | Not Implemented |
WV0323 # 11 Y:2005 | 11 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $553 | $1,108 | Not Implemented |
WV0323 # 12 Y:2005 | 12 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $436 | $715 | Not Implemented |
WV0323 # 13 Y:2005 | 13 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $428 | $140 | Not Implemented |
WV0323 # 14 Y:2005 | 14 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $197 | $138 | Not Implemented |