Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,577
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0155 # 09 Y:1989 | 09 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $150 | $200 | Implemented |
AM0060 # 01 Y:1989 | 01 | 1989 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $59,200 | $0 | Implemented |
AM0060 # 02 Y:1989 | 02 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,080 | $24,686 | Not Implemented |
AM0060 # 03 Y:1989 | 03 | 1989 | COVER OPEN TANKS | $9,300 | $0 | Implemented |
AM0060 # 04 Y:1989 | 04 | 1989 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $2,440 | $900 | Not Implemented |
AM0060 # 05 Y:1989 | 05 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,320 | $0 | Not Implemented |
AM0060 # 06 Y:1989 | 06 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,210 | $940 | Not Implemented |
AM0060 # 07 Y:1989 | 07 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $540 | $420 | Not Implemented |
AM0060 # 08 Y:1989 | 08 | 1989 | INSULATE BARE EQUIPMENT | $1,080 | $1,080 | Implemented |
UD0280 # 01 Y:1989 | 01 | 1989 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $14,040 | $14,400 | Implemented |
UD0280 # 02 Y:1989 | 02 | 1989 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,566 | $7,000 | Implemented |
UD0280 # 03 Y:1989 | 03 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $16,696 | $0 | Implemented |
UD0280 # 04 Y:1989 | 04 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,314 | $0 | Implemented |
UD0280 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $825 | $0 | Implemented |
UD0280 # 06 Y:1989 | 06 | 1989 | INSTALL STORM WINDOWS AND DOORS | $955 | $1,920 | Implemented |
RU0046 # 01 Y:1989 | 01 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $422 | $134 | Not Implemented |
RU0046 # 02 Y:1989 | 02 | 1989 | INSULATE BARE EQUIPMENT | $1,836 | $682 | Implemented |
RU0046 # 03 Y:1989 | 03 | 1989 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,698 | $0 | Implemented |
RU0046 # 04 Y:1989 | 04 | 1989 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $4,001 | $8,500 | Not Implemented |
RU0046 # 05 Y:1989 | 05 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,552 | $6,800 | Not Implemented |
RU0046 # 06 Y:1989 | 06 | 1989 | CLOSE OFF UNNEEDED STEAM LINES | $1,773 | $1,880 | Implemented |
CO0139 # 01 Y:1988 | 01 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $427 | $150 | Implemented |
CO0139 # 02 Y:1988 | 02 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $490 | $200 | Implemented |
CO0139 # 03 Y:1988 | 03 | 1988 | REDUCE VENTILATION AIR | $567 | $200 | Implemented |
CO0139 # 04 Y:1988 | 04 | 1988 | INSULATE BARE EQUIPMENT | $502 | $1,485 | Not Implemented |