Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
23
matching recommendationsSIC | 347 | Metal Services, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0401 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,618 | $17,144 | Not Implemented |
BD0401 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $2,085 | $900 | Not Implemented |
BD0401 # 04 Y:2011 | 04 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,685 | $3,000 | Not Implemented |
BD0401 # 05 Y:2011 | 05 | 2011 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,724 | $1,500 | Not Implemented |
BD0401 # 06 Y:2011 | 06 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,081 | $550 | Not Implemented |
BD0401 # 01 Y:2011 | 01 | 2011 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $5,625 | $4,500 | Not Implemented |
IA0464 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,737 | $33,313 | Implemented |
IA0464 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,378 | $7,606 | Implemented |
IA0464 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,295 | $10,281 | Implemented |
IA0464 # 04 Y:2011 | 04 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,199 | $45 | Implemented |
IA0464 # 03 Y:2011 | 03 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $380 | $15 | Implemented |
IA0464 # 02 Y:2011 | 02 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $387 | $290 | Implemented |
IA0464 # 01 Y:2011 | 01 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $1,766 | $700 | Implemented |
UM0383 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,263 | $23,909 | Not Implemented |
UM0383 # 02 Y:2011 | 02 | 2011 | OPTIMIZE PLANT POWER FACTOR | $9,728 | $5,670 | Not Implemented |
UM0383 # 03 Y:2011 | 03 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $3,151 | $7,125 | Not Implemented |
UM0383 # 04 Y:2011 | 04 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,089 | $1,291 | Not Implemented |
UM0383 # 05 Y:2011 | 05 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,601 | $7,500 | Not Implemented |
UM0383 # 06 Y:2011 | 06 | 2011 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,466 | $4,400 | Not Implemented |
UM0383 # 07 Y:2011 | 07 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,452 | $7,236 | Not Implemented |
UM0383 # 08 Y:2011 | 08 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,035 | $1,207 | Not Implemented |
UM0383 # 09 Y:2011 | 09 | 2011 | TREAT AND REUSE RINSE WATERS | $60,914 | $25,231 | Not Implemented |
UM0383 # 10 Y:2011 | 10 | 2011 | HEAT WATER WITH EXHAUST HEAT | $101,682 | $74,000 | Not Implemented |