Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
145
matching recommendationsSIC | 3471 | Plating And Polishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0143 # 02 Y:1996 | 02 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,102 | $550 | Implemented |
SD0143 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,180 | $4,458 | Implemented |
SD0143 # 04 Y:1996 | 04 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,099 | $2,480 | Implemented |
SD0143 # 05 Y:1996 | 05 | 1996 | INSTALL OCCUPANCY SENSORS | $874 | $410 | Implemented |
SD0143 # 06 Y:1996 | 06 | 1996 | SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED | $16,297 | $1,450 | Implemented |
SD0143 # 07 Y:1996 | 07 | 1996 | TREAT AND REUSE RINSE WATERS | $1,000 | $280 | Implemented |
SD0143 # 08 Y:1996 | 08 | 1996 | TREAT AND REUSE RINSE WATERS | $765 | $200 | Implemented |
SF0072 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $510 | $0 | Implemented |
SF0072 # 02 Y:1995 | 02 | 1995 | USE SYNTHETIC LUBRICANT | $79 | $169 | Implemented |
SF0072 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,389 | $1,123 | Not Implemented |
SF0072 # 04 Y:1995 | 04 | 1995 | COVER OPEN TANKS | $98 | $77 | Implemented |
SF0072 # 05 Y:1995 | 05 | 1995 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $462 | $250 | Implemented |
SF0072 # 06 Y:1995 | 06 | 1995 | REDUCE WATER USE WITH COUNTER CURRENT RINSING | $4,047 | $933 | Not Implemented |
SF0061 # 01 Y:1995 | 01 | 1995 | INSTALL OCCUPANCY SENSORS | $1,935 | $360 | Not Implemented |
SF0061 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $129 | $170 | Implemented |
SF0061 # 03 Y:1995 | 03 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $347 | $1,570 | Not Implemented |
SF0061 # 04 Y:1995 | 04 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,658 | $2,208 | Implemented |
SF0061 # 05 Y:1995 | 05 | 1995 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $733 | $1,300 | Not Implemented |
SF0061 # 06 Y:1995 | 06 | 1995 | COVER OPEN TANKS | $3,373 | $1,560 | Not Implemented |
SF0061 # 07 Y:1995 | 07 | 1995 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $6,048 | $2,955 | Not Implemented |
SF0061 # 08 Y:1995 | 08 | 1995 | USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE | $2,880 | $25,300 | Not Implemented |
SF0061 # 09 Y:1995 | 09 | 1995 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $7,532 | $1,288 | Implemented |
SF0061 # 10 Y:1995 | 10 | 1995 | TREAT AND REUSE RINSE WATERS | $10,340 | $6,344 | Not Implemented |
SF0019 # 01 Y:1994 | 01 | 1994 | USE POWER DURING OFF-PEAK PERIODS | $6,225 | $4,000 | Implemented |
SF0019 # 02 Y:1994 | 02 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,939 | $800 | Implemented |