Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
373
matching recommendationsSIC | 348 | Ordnance And Accessories, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0399 # 06 Y:2015 | 06 | 2015 | REPLACE BOILER | $16,753 | $20,000 | Not Implemented |
LE0399 # 05 Y:2015 | 05 | 2015 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,395 | $3,600 | Not Implemented |
UD0930 # 08 Y:2015 | 08 | 2015 | COVER OPEN TANKS | $5,393 | $300 | Implemented |
UD0930 # 07 Y:2015 | 07 | 2015 | INSTALL COMMON HEADER ON COMPRESSORS | $5,330 | $1,018 | Implemented |
UD0930 # 06 Y:2015 | 06 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $13,067 | $17,500 | Not Implemented |
UD0930 # 05 Y:2015 | 05 | 2015 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $43,664 | $10,000 | Not Implemented |
UD0930 # 04 Y:2015 | 04 | 2015 | REPLACE WATER COOLING ON PROCESSES WITH AIR COOLING | $34,411 | $5,100 | Implemented |
UD0930 # 03 Y:2015 | 03 | 2015 | USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) | $2,426 | $300 | Not Implemented |
UD0930 # 02 Y:2015 | 02 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,352 | $0 | Implemented |
UD0930 # 01 Y:2015 | 01 | 2015 | INSTALL OCCUPANCY SENSORS | $59,188 | $0 | Implemented |
UD0930 # 09 Y:2015 | 09 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,032 | $19,284 | Not Implemented |
SU0382 # 01 Y:2015 | 01 | 2015 | USE SYNTHETIC LUBRICANT | $362 | $0 | Not Implemented |
SU0382 # 02 Y:2015 | 02 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,982 | $1,901 | Not Implemented |
SU0382 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $394 | $320 | Not Implemented |
SU0382 # 04 Y:2015 | 04 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,679 | $10,400 | Not Implemented |
SU0382 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $220 | $624 | Not Implemented |
SU0382 # 06 Y:2015 | 06 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $461 | $1,590 | Not Implemented |
SU0382 # 07 Y:2015 | 07 | 2015 | INSTALL OCCUPANCY SENSORS | $394 | $1,415 | Not Implemented |
SU0382 # 08 Y:2015 | 08 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $68 | $324 | Not Implemented |
BS0048 # 03 Y:2015 | 03 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,403 | $5,220 | Implemented |
BS0048 # 01 Y:2015 | 01 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,298 | $28,509 | Implemented |
BS0048 # 02 Y:2015 | 02 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,926 | $9,550 | Implemented |
BS0048 # 04 Y:2015 | 04 | 2015 | INSTALL OCCUPANCY SENSORS | $1,240 | $1,650 | Not Implemented |
BS0048 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $181 | $540 | Not Implemented |
BS0048 # 06 Y:2015 | 06 | 2015 | INSULATE BARE EQUIPMENT | $1,969 | $3,083 | Implemented |